Evidence map›Paper›PMID 42016462›Full record

ArticleFrontiers in dental medicine2026

Effect of distal cantilever and anterior implant diameter on framework and cortical bone stress in a PEEK-based All-on-Four mandibular prosthesis.

Shobha Rodrigues, Sandipan Mukherjee, Reon David Sequeira, Krishna Kumar P, Nithesh Naik, Prashant Bajantri, Sowmya N, Shivani Shetty, Vathsala Patil

Abstract read
In one paragraph

Article in Frontiers in dental medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Shobha RodriguesDepartment of Prosthodontics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, India.
Sandipan MukherjeeDepartment of Prosthodontics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, India.
Reon David SequeiraManipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India.
Krishna Kumar PManipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India.
Nithesh NaikManipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India.
Prashant BajantriDepartment of Prosthodontics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, India.
Sowmya NDepartment of Prosthodontics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, India.
Shivani ShettyDepartment of Prosthodontics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, India.
Vathsala PatilDepartment of Oral Medicine and Radiology, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Polyetheretherketone (PEEK) has been proposed as an alternative framework material for full-arch implant-supported prostheses due to its lower elastic modulus relative to metallic frameworks. However, quantitative data regarding the combined biomechanical influence of distal cantilever extension and anterior implant diameter in PEEK-based mandibular All-on-Four rehabilitations remain limited. Purpose: To quantify the effects of distal cantilever presence and anterior implant diameter (3.5 mm vs. 4.5 mm) on framework stress and peri-implant cortical bone response in a PEEK-based mandibular All-on-Four prosthesis using three-dimensional finite element analysis. Methods: Four implant configurations were modeled: Standard-NC (4.5 mm anterior, no cantilever), Mixed-NC (3.5/4.5 mm anterior, no cantilever), Standard-C (4.5 mm anterior, with cantilever), and Mixed-C (3.5/4.5 mm anterior, with cantilever). A 300 N static load was applied at premolar and molar positions under vertical (0°) and 30° oblique loading. Peak von Mises stress in the PEEK framework and crestal cortical bone, along with maximum principal cortical strain, were recorded. Results: Distal cantilever extension increased peak framework stress by up to 59% under premolar vertical loading (222.24 MPa vs. 139.60 MPa) and increased crestal cortical stress by approximately 49% (18.36 MPa vs. 12.31 MPa) compared with the non-cantilevered baseline configuration. Under molar vertical loading, maximum principal strain increased by approximately 105% in the Mixed-C model compared to the Standard-NC configuration (0.0080 vs. 0.0039). Reduction of anterior implant diameter increased cortical strain by approximately 28-31% in non-cantilevered models and further amplified strain when combined with cantilever extension. Peak framework stresses reached 222.24 MPa in localized regions. Conclusion: Distal cantilever extension was the primary determinant of biomechanical amplification in a PEEK-based mandibular All-on-Four prosthesis, while reduced anterior implant diameter exerted a secondary but additive effect. These findings highlight the mechanical sensitivity of low-modulus framework systems to cantilever geometry and implant diameter in full-arch rehabilitations.

Indexed as

All-on-Fourbiomechanical performancecantileverfinite element analysisimplant diametermandibular prosthesisPEEK framework

Identifiers

PMID42016462
PMCPMC13093877

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.