Evidence map›Paper›PMID 42012574›Full record

ArticleInternational journal of computer assisted radiology and surgery2026

Path planning for fracture reduction robots incorporating physiological tissue response and safety-oriented optimization.

Pengyun Liu, QianXin Wang, Bin Shi, Ye Peng, Jianqiu Hu, Shibo Cai, Faqin Lv, Lihai Zhang

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Pengyun LiuCollege of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, 310023, Zhejiang, China.ORCID http://orcid.org/0009-0001-2874-9131
QianXin WangCollege of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, 310023, Zhejiang, China.
Bin ShiDepartment of Orthopaedics, Chinese PLA General Hospital, Beijing, 100853, China.
Ye PengDepartment of Orthopaedics, Chinese PLA General Hospital, Beijing, 100853, China.
Jianqiu HuDepartment of Ultrasound, Hainan Hospital of Chinese PLA General Hospital, Sanya, 572013, China.
Shibo CaiSchool of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, 310018, Zhejiang, China. ccccc@cjlu.edu.cn.
Faqin LvDepartment of Ultrasound, Chinese PLA General Hospital, Beijing, 100853, China. lvfq301@163.com.
Lihai ZhangDepartment of Orthopaedics, Chinese PLA General Hospital, Beijing, 100853, China. zhanglihai74@qq.com.

Funding

National Key Research and Development Program of China 2023YFB4603200National Natural Science Foundation of China U23A20345
6 · The paper itself

Abstract

purposeRobot-assisted orthopedic reduction faces the dual challenge of achieving geometric precision while preserving physiological safety. This study presents a physiology-driven, multi-objective path-planning framework to optimize both surgical efficiency and tissue protection.

methodsA three-zone monitoring system-Doctor-Control, Bone-Response, and Tissue-Impact-was established in animal experiments to simultaneously record robotic kinematics, bone motion, and vascular-neural physiological signals. Correlation analyses identified strong coupling between mechanical motion and physiological responses, which guided the development of a multi-objective optimization framework combining Rapidly exploring Random Tree (RRT) and Non-dominated Sorting Genetic Algorithm II (NSGA-II). The planner minimized both geometric path length and physiological disturbance.

resultsSignificant relationships were observed between femur-tibia displacement and femoral (r = - 0.90, p = 0.033) and iliac (r = 0.89, p = 0.033) artery flow. Tibial and distal femur rotations markedly reduced sciatic nerve conduction amplitude (

conclusionThe physiology-driven optimization framework enables safe and efficient robotic fracture reduction by integrating multi-modal physiological feedback into path planning. These results demonstrate its potential for intelligent, safety-aware surgical robotics.

Indexed as

Fracture reductionMulti-objective optimizationPhysiological safetyRobotic surgeryTissue response modeling

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.