Evidence map›Paper›PMID 42012530›Full record

ArticleWorld journal of urology2026

Correlation of simultaneously monitored intrarenal and irrigation pressures during ureteroscopy: an in vivo pilot study.

Ahmet Baris Aydin, Mehmet Guven Gunver, İsmail Taha Gürlek, Sude Yarar, Faruk Özcan, Olivier Traxer, Tzevat Tefik

Abstract read
PubMed Publisher
In one paragraph

Article in World journal of urology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ahmet Baris AydinDepartment of Urology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Türkiye. abarisaydn@gmail.com.ORCID http://orcid.org/0000-0001-9592-6057
Mehmet Guven GunverDepartment of Biostatistics, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Türkiye, Turkey.ORCID http://orcid.org/0000-0002-4628-8391
İsmail Taha GürlekIstanbul Faculty of Medicine, Istanbul University, Istanbul, Türkiye.ORCID http://orcid.org/0009-0001-6616-5022
Sude YararIstanbul Faculty of Medicine, Istanbul University, Istanbul, Türkiye.ORCID http://orcid.org/0009-0007-8558-3709
Faruk ÖzcanDepartment of Urology, Division of Urological Oncology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Türkiye.ORCID http://orcid.org/0000-0001-7544-6638
Olivier TraxerPETRA UroGroup, Paris, France.ORCID http://orcid.org/0000-0002-2459-3803
Tzevat TefikDepartment of Urology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Türkiye.ORCID http://orcid.org/0000-0002-1398-8332

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to evaluate the relationship between irrigation pressure and intrarenal pressure during ureteroscopy and to assess whether intrarenal pressure trends could be inferred via the flexible ureteroscope working channel using the pump release technique, with antegrade percutaneous measurement as the reference. PATIENTS AND

methodsPressures were recorded during ureteroscopic lithotripsy in nineteen patients undergoing endoscopic combined intrarenal surgery. Intrarenal pressure was continuously measured via an antegrade Chiba needle placed, whenever feasible, into the lower posterior calyx or otherwise into the calyx nearest to the stone, and connected to a pressure transducer. Irrigation pressure was continuously and concurrently recorded from the proximal irrigation line of the ureteroscope using a second transducer. Correlation analyses were performed. We also assessed whether intrarenal pressure could be estimated using the pump release technique, in which sudden release of the irrigation pump interrupts flow and creates a transient static column approximating intrarenal pressure.

resultsA total of 3 h and 53 min of pressure data were recorded. Mean irrigation (PIrr) and intrarenal pressures (IRP, measured via the Chiba needle) were 56.6 mmHg and 34.1 mmHg, respectively. Moderate correlations were identified between PIrr and IRP during gravity irrigation (r = 0.506) and between their peak values (r = 0.49). During PRT, a significant correlation was observed between PIrr and simultaneous IRP over brief intervals (r = 0.602–0.613).

conclusionsUsing external pressure transducers on irrigation lines to estimate intrarenal pressure trends during ureteroscopy is feasible. Larger studies are needed to validate this method and to account for factors that may influence pressure accuracy.

Indexed as

KidneyKidney CalculiLithotripsyMonitoring, IntraoperativeTherapeutic IrrigationUreteroscopyFemaleHumansMaleMiddle AgedPilot ProjectsPressureCalculi, urinaryMonitoring, intraoperativeNephrolithiasisPressureUreteroscopy

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.