ArticleScientific reports2026
Development and validation of ratio spectra manipulation methods for the determination of etoricoxib and tramadol in binary mixtures.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Two simple and selective spectrophotometric methods, ratio difference and derivative ratio, were developed and validated for the simultaneous determination of etoricoxib and tramadol in binary mixtures and pharmaceutical formulations. The methods effectively resolved the sever spectral overlap of both drugs without prior separation. In the ratio difference method, amplitude differences between 294 and 239 nm for etoricoxib and 218 and 272 nm for tramadol showed excellent linearity. In the derivative ratio method, derivative amplitudes measured at 287 nm etoricoxib, and 229 nm tramadol provided high selectivity and sensitivity. The linear ranges were 2-23 µg/mL for etoricoxib and 3-40 µg/mL for tramadol, with correlation coefficients above 0.999. Both methods achieved recoveries between 98.78 and 101.09% and precision values (%RSD) below 2%. Statistical comparison with a reported HPLC method showed no significant difference. The proposed methods are accurate, cost-effective, and supported by AGREE-based greenness assessment, making them suitable for routine quality control of etoricoxib and tramadol formulations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.