Evidence map›Paper›PMID 42009785›Full record

ArticleScientific reports2026

Design of a soft robotic endoscope with enhanced bending and AI-based prediction.

Miriam Hani, Mohamed N Elghitany, Rania Sweif, Shady A Maged

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Miriam HaniMechatronics Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, 11566, Egypt. e07952@eng.asu.edu.eg.
Mohamed N ElghitanyMechatronics Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, 11566, Egypt.
Rania SweifElectrical Power Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, 11566, Egypt.
Shady A MagedMechatronics Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, 11566, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Minimally invasive surgery (MIS) increasingly benefits from soft robotic platforms that offer enhanced compliance and safer human-robot interaction. However, one of the most important challenges of design is still to achieve larger bending at low actuation pressure while maintaining structural integrity. This paper introduces a proposed novel soft robotic endoscope aimed at maximizing bending performance and reducing needed pressure in complex surgeries below the maximum limit of blood pressure, which is 0.24 bar (Boutouyrie in Hypertension 34(4):475-480, 1999), to enhance patients' safety and reduce their trauma. The proposed design demonstrates significant improvements in both bending angle and operating pressure compared to existing architecture. Finite element modeling was utilized to evaluate the performance of the novel design under several test cases. Then, machine learning techniques were implemented to develop an Artificial Intelligence (AI) model aimed at predicting the most effective parameters needed for testing the design. Instead of implementing Finite Element Analysis for each new design, a highly accurate model will now predict bending angle, twisting angle, bending speed and twisting speed for the proposed design under any input pressure conditions. Experimental validation was developed by fabricating the module and testing it to validate the proposed design's performance. The results show that the proposed design achieves higher bending angles at same pressures, compared to previous designs, under the specified design conditions.

Indexed as

Artificial IntelligenceEndoscopesEndoscopyEquipment DesignRoboticsRobotic Surgical ProceduresFinite Element AnalysisHumansMachine LearningMinimally Invasive Surgical ProceduresArtificial neural networksBending angleEndoscopeFinite element analysisSupport vector machineSurgical applications

Identifiers

PMID42009785
PMCPMC13096537

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.