ArticleNature communications2026
Improved dynamic MRI of the wrist and heart at 0.55 T enabled by rapid 3D printed flexible coils.
Article in Nature communications, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Dynamic MRI at low field is limited by reduced signal-to-noise ratio (SNR) and additional losses imposed by accelerated acquisitions required for high temporal resolution. Flexible, anatomically conformal coils can recover SNR by maintaining proximity during motion, but lower conductor conductivity introduces resistive losses, requiring careful material optimization. We demonstrate high-quality dynamic imaging at 0.55 T using coils fabricated via two rapid, low-cost digital methods: direct-ink-write silver printing and screen printing of copper-doped EGaIn. Four-element wrist arrays were fabricated in 8 minutes per element at approximately $30 in consumable materials. In three subjects, both arrays achieved up to 4 × higher contrast and 5 × greater sharpness than a commercial coil during dynamic wrist imaging. To demonstrate generalizability, a seven-element silver-ink cardiac array produced cine images comparable to a commercial coil. These results establish digitally fabricated flexible coils as a scalable and accessible solution for dynamic musculoskeletal and cardiac MRI at low field.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.