In one paragraph

Article in Nature communications, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Félix MuñozAlfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA.
Ye TianMing Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA, USA.
Ted LêThe Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA, USA.
Jaehwan JangDepartment of Medical Engineering, Yonsei University, Seoul, Republic of Korea.
Helmut StarkStark Contrast LLC, Erlangen, Germany.
Mohammad Shafiqul IslamThe Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA, USA.ORCID http://orcid.org/0000-0002-0998-3643
Min-Gu KimDepartment of Medical Engineering, Yonsei University, Seoul, Republic of Korea.ORCID http://orcid.org/0000-0001-6038-1448
Krishna S NayakAlfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA.ORCID http://orcid.org/0000-0001-5735-3550
Yasser KhanAlfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA. yasser.khan@usc.edu.ORCID http://orcid.org/0000-0003-2290-0854

Funding

National Science Foundation (NSF) 1828736
6 · The paper itself

Abstract

Dynamic MRI at low field is limited by reduced signal-to-noise ratio (SNR) and additional losses imposed by accelerated acquisitions required for high temporal resolution. Flexible, anatomically conformal coils can recover SNR by maintaining proximity during motion, but lower conductor conductivity introduces resistive losses, requiring careful material optimization. We demonstrate high-quality dynamic imaging at 0.55 T using coils fabricated via two rapid, low-cost digital methods: direct-ink-write silver printing and screen printing of copper-doped EGaIn. Four-element wrist arrays were fabricated in 8 minutes per element at approximately $30 in consumable materials. In three subjects, both arrays achieved up to 4 × higher contrast and 5 × greater sharpness than a commercial coil during dynamic wrist imaging. To demonstrate generalizability, a seven-element silver-ink cardiac array produced cine images comparable to a commercial coil. These results establish digitally fabricated flexible coils as a scalable and accessible solution for dynamic musculoskeletal and cardiac MRI at low field.

Indexed as

HeartMagnetic Resonance ImagingPrinting, Three-DimensionalWristEquipment DesignHumansSignal-To-Noise Ratio

Identifiers

PMID42009681
PMCPMC13284225

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.