ArticleVeterinary and animal science2026
Electroencephalography, behavioural observations, bleed-out and temperature at the point of application in cattle receiving DTS: Diathermic Syncope® at 160-200 kJ.
Article in Veterinary and animal science, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Society expects that animals brought to slaughter are killed humanely, taking care to manage and maintain their welfare. Rendering the animal unconscious while minimising pain, fear, or distress is one key expectation, while unconsciousness lasting long enough for the animal to die through loss of blood without regaining consciousness is another. A dielectric (electromagnetic) system, trademarked DTS: Diathermic Syncope® (DTS) has the potential to address these requirements. Twelve cattle were rendered unconscious using DTS with 160-200 kJ of energy delivered at 18 kW. In addition to Electroencephalography (EEG) the animals were carefully observed from the time of entry into the restraint until they had fully bled out for signs that could indicate consciousness. There was little sign of pain, fear or distress, in the restraint box or during energy application. Both EEG and behavioural observation confirmed that DTS induced Grand mal epilepsy in the cattle consistent with unconsciousness, within a few seconds of energy application. There was no rise in forehead temperature at the site of energy application while the animals were conscious. Later rises in temperature could result in superficial burns. The animals remained unconscious while the neck cut was applied and then bled strongly without regaining consciousness. The significant blood loss met the expectation of religious slaughter.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.