ArticleACS measurement science au2026
Symmetrical pH Electrochemical Cell Coupled to Constant Potential Coulometry for Improved Sensitivity and Precision: Part 1. Fundamental Considerations.
Article in ACS measurement science au, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
pH is a major variable in complex aquatic ecosystems, influencing biological activity, metal speciation and more. The method to routinely measure pH is potentiometric measurements with a glass electrode connected to a reference Ag/AgCl element in contact with the sample through a liquid junction. However, it has been largely replaced by optical pH assays in the field of seawater pH measurements because much better precisions could be achieved. Glass electrodes also suffer from bias such as liquid junction potential changes and temperature influence on the inner solution pH that generate inaccuracies. Moreover, the Nernstian relationship between observed potential and pH results in limited sensitivity. To overcome these limitations, an alternative readout called constant potential coulometry is implemented in the measurement system for increased sensitivity. A symmetrical pH cell is proposed in which two identical glass electrodes, separated by an open 3 M KCl channel, are measured against each other. One of them is kept in a NIST buffer while the other is used to measure the pH of the sample or the calibrant solution. Glass electrodes are evaluated at different temperatures in NIST buffers versus a classical reference electrode and versus each other in a symmetrical flow cell. The latter features open junctions that should improve the repeatability of the liquid junction potential. The determined signal repeatability in a single sample is as low as 0.3 mpH with a precision for consecutive samples of 0.001 pH, which is drastically improved over routinely available pH probes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.