Evidence map›Paper›PMID 42006926›Full record

ArticleBrain & spine2026

Accuracy and effectiveness of thoracolumbar pedicle screw placement with a mixed reality head mounted device: first clinical experience and results.

Bernardo Reyes Medina, Fatemeh Khafaji, Safwan Saffour, Christoph Sippl, Stefan Linsler

Abstract read
In one paragraph

Article in Brain & spine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Bernardo Reyes MedinaKlinik für Neurochirugie, Klinikum Bayreuth, Institut für Lehre und Forschung Medizincampus Oberfranken MCO, Friedrich-Alexander-Universität Erlangen-Nürnberg, 95455 Bayreuth, Deutschland.
Fatemeh KhafajiKlinik für Neurochirugie, Klinikum Bayreuth, Institut für Lehre und Forschung Medizincampus Oberfranken MCO, Friedrich-Alexander-Universität Erlangen-Nürnberg, 95455 Bayreuth, Deutschland.
Safwan SaffourKlinik für Neurochirugie, Klinikum Bayreuth, Institut für Lehre und Forschung Medizincampus Oberfranken MCO, Friedrich-Alexander-Universität Erlangen-Nürnberg, 95455 Bayreuth, Deutschland.
Christoph SipplKlinik für Neurochirugie, Klinikum Bayreuth, Institut für Lehre und Forschung Medizincampus Oberfranken MCO, Friedrich-Alexander-Universität Erlangen-Nürnberg, 95455 Bayreuth, Deutschland.
Stefan LinslerKlinik für Neurochirugie, Klinikum Bayreuth, Institut für Lehre und Forschung Medizincampus Oberfranken MCO, Friedrich-Alexander-Universität Erlangen-Nürnberg, 95455 Bayreuth, Deutschland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Mixed reality (MR) has the potential to enhance the accuracy and effectiveness of spine surgery, particularly in the placement of pedicle screws. This technology can lead to improved outcomes, optimized ergonomics, and reduced operative time and costs. Research question: This study evaluates the efficacy and accuracy of MR in thoracolumbar pedicle screw placement using neuronavigation and a head-mounted device. Material and methods: We conducted a prospective review of the initial series of thoracolumbar pedicle screw placements utilizing neuronavigation (Brainlab) and MR with a head-mounted device (MagicLeap2). Data from 22 patients were analyzed, involving a total of 144 pedicle screws placed. The Gertzbein-Robbins classification (GRC) was used to assess screw position: Grade A (screw within the pedicle), Grade B (breach <2 mm), Grade C (breach 2-4 mm), Grade D (breach 4-6 mm), and Grade E (breach >6 mm). Grades A and B were considered accurate placements. Results: Out of 144 thoracolumbar pedicle screws, 139 were accurately positioned according to GRC grades A and B, resulting in a clinical accuracy rate of 96.5%. The mean deviation at the bone entry point compared to preoperative plans was 2.35 ± 1.1 mm, with a mean angular deviation of 3.1 ± 1.4°. Surgeons reported no issues with the head-mounted device, including dizziness or headaches, and noted no limitations in visualization of the surgical field. Discussion and conclusion: This study demonstrates the successful application of MR combined with neuronavigation for precise pedicle screw placement, eliminating the need for fluoroscopy and enhancing surgical efficiency.

Indexed as

Augmented realityHead mounted deviceMixed realityNavigationSpine surgeryTechniques and innovationsThoracolumbar screw placement

Identifiers

PMID42006926
PMCPMC13089029

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials