Geometric accuracy of surface high-dose rate brachytherapy applicator and catheters identified using Dixon volumetric interpolated breath-hold examination magnetic resonance images.
Article in Physics and imaging in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and purpose: Volumetric Interpolated Breath-hold Examination (VIBE) magnetic resonance imaging (MRI) can depict flap applicators of High-Dose-Rate (HDR) surface brachytherapy. Evaluating criteria for catheter detection and assessing the geometric fidelity of detected applicators and catheters is important for VIBE implementation in HDR brachytherapy planning. Materials and methods: A fixed flat Freiburg Flap (FF) applicator (31 empty catheters, 21 spheres each) was imaged axially in a computed tomography (CT) scanner and 3 T MR simulator using Dixon VIBE. VIBE was repeated for three sagittal and coronal applicator placements. A novel algorithm detected applicator borders and catheters on central slices of in-phase (IP) and opposed-phase (OP) series, their geometric mean (GM), and reference CT scans. Obtained distances were compared against known dimensions. Applicator and catheter edge displacements between IP and OP images were measured. Results: All catheters were automatically identified on all series. Applicator lengths generally lay within 310 ± 1 mm. Catheter lengths were underestimated by up to 2 mm on original images due to reliance on surrogate tunneled beads. Adjacent catheter positions lay on average within 0.05 mm from their nominal 10.0 mm distance. Catheter angles were opposite between IP and OP images affected by chemical shift. GM corrected the relative applicator and catheter rotation. Average chemical shift induced IP-OP displacements were 2.3 ± 0.6 mm. Conclusions: Local signal intensity minima were reliable for empty catheter detection. Applicator shape and dimensions were preserved on individual IP and OP series. Chemical shift induced displacements amounted to 1.2 mm for individual images.