Evidence map›Paper›PMID 42005561›Full record

ArticleJHLT open2026

A novel less invasive single port pulsatile ventricular assist device.

Li Li, Jinsong Chen, Zhongjiang Zhuang, Stephen Topaz, Masashi Kawabori, Joseph B Zwischenberger, Cherry Ballard-Croft, Dongfang Wang

Abstract read
In one paragraph

Article in JHLT open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Li LiDepartment of Surgery, University of Kentucky, Lexington, Kentucky.
Jinsong ChenW-Z Biotech, LLC, Lexington, Kentucky.
Zhongjiang ZhuangW-Z Biotech, LLC, Lexington, Kentucky.
Stephen TopazW-Z Biotech, LLC, Lexington, Kentucky.
Masashi KawaboriDepartment of Surgery, University of Kentucky, Lexington, Kentucky.
Joseph B ZwischenbergerDepartment of Surgery, University of Kentucky, Lexington, Kentucky.
Cherry Ballard-CroftDepartment of Surgery, University of Kentucky, Lexington, Kentucky.
Dongfang WangDepartment of Surgery, University of Kentucky, Lexington, Kentucky.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A less invasive paracorporeal single port pulsatile ventricular assist device (sppVAD) was developed for cardiogenic shock. This compact sppVAD includes a valved single lumen cannula (VSLC), valveless single port diaphragm displacement pump (spDDP), and portable console. A 33/27 Fr VSLC was fabricated for mock loop testing, a 28/25 Fr VSLC was made for 6 hours sheep testing (n = 5, 44-52 kg), and valveless spDDP with portable console was made. The sppVAD (33/27 Fr VSLC) achieved 6.2 L/min flow in mock loop. In sheep, the 28/25 Fr VSLC was inserted without cardiopulmonary bypass from apex to ascending aorta within 1 minute after apex exposure. The sppVAD achieved 3.75 L/min flow in sheep with stable hemodynamics. Hemoglobin, free hemoglobin, and platelet/white blood cell counts were unchanged through 6 hours. Thus, our less invasive sppVAD achieved total left ventricle support with acceptable short-term hemocompatibility, showing good promise as a temporary VAD for cardiogenic shock.

Indexed as

Cardiogenic shockMechanical circulatory supportSheepVentricular assist device

Identifiers

PMID42005561
PMCPMC13087685

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.