Evidence map›Paper›PMID 42005459›Full record

ArticleFrontiers in bioengineering and biotechnology2026

Design and experimental study of a rigid-flexible coupled back rehabilitation robot.

Delin Kong, Yage Wang, Fu Mo, Chunbao Wang, Zhiwei Huang, Ting Ouyang

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Delin KongSchool of Mechanical and Electrical Engineering, Guangdong University of Science and Technology, Dongguan, China.
Yage WangSchool of Mechanical and Electrical Engineering, Guangdong University of Science and Technology, Dongguan, China.
Fu MoSchool of Mechanical and Electrical Engineering, Guangdong University of Science and Technology, Dongguan, China.
Chunbao WangSchool of Mechanical and Electrical Engineering, Guangdong University of Science and Technology, Dongguan, China.
Zhiwei HuangSchool of Mechanical and Electrical Engineering, Guangdong University of Science and Technology, Dongguan, China.
Ting OuyangSchool of Mechanical and Electrical Engineering, Guangdong University of Science and Technology, Dongguan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Existing spinal rehabilitation mechanisms present several limitations. These include a restricted range of motion, low flexibility, and suboptimal comfort. Methodology: To overcome these issues, a novel rigid-flexible coupled spine parallel rehabilitation mechanism is proposed. The mechanism is supported by a compression spring to enhance adaptability and comfort. Initially, a simplified skeletal-muscular model of spinal motion was developed based on human spine analysis. Subsequently, a mathematical model describing the system's kinematics was established. Results: Analysis of the model indicated that, under a 120 N force applied by the anterior deltoid fascicle, the mechanism exhibited a maximum deformation of 6.40 mm, meeting the design expectations. In both simulations and experimental tests of forward flexion, the maximum lumbar dorsal forward flexion angle reached 68.6°. The maximum lateral flexion angle achieved was 60.4°, while the maximum rotational angle reached 58.5°. The average maximum movement speed across different volunteers was 14.94°/s, closely aligning with the design target of 14.90°/s. Experimental measurements of the device's activity angles showed averages of 37.6° for forward flexion, 13.56° for backward flexion, 13.62° for lateral flexion (left/right), and 17.5° for rotation (left/right). All measured values were within, or closely approximated, the design range targets. Conclusion: The study determined both the physiological movement range of the human spine and the effective working space of the proposed mechanism. The results confirm the rationality and effectiveness of the mechanism's design.

Indexed as

back rehabilitation robotcompression spring supporthuman spine kinematicslumbar motion analysisrigid-flexible couplingspine rehabilitation mechanism

Identifiers

PMID42005459
PMCPMC13084161

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.