Evidence map›Paper›PMID 42003891›Full record

ArticleInternational journal of exercise science2026

Acute Effects of Thoracic-Spinal Elevation via a Novel Bench Press Pad on sEMG and Barbell Kinetics in Resistance-Trained Males.

Joshua A Kidwell, Trent Yamamoto, Kyle J Hetherton, Nathan Truneh, Jacob J Bright, August E Blatney, Phillip Goldman, Eric Neufeld, Brett A Dolezal

Abstract read
In one paragraph

Article in International journal of exercise science, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Joshua A KidwellCreighton University School of Medicine, Omaha, NE, USA.
Trent YamamotoAirway and UC Fit Digital Health-Exercise Physiology Research Laboratory, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA.
Kyle J HethertonAirway and UC Fit Digital Health-Exercise Physiology Research Laboratory, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA.
Nathan TrunehAirway and UC Fit Digital Health-Exercise Physiology Research Laboratory, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA.
Jacob J BrightAirway and UC Fit Digital Health-Exercise Physiology Research Laboratory, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA.
August E BlatneyAirway and UC Fit Digital Health-Exercise Physiology Research Laboratory, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA.
Phillip GoldmanBaylor College of Medicine, Houston, TX, USA.
Eric NeufeldNorthwell Orthopedics. New Hyde Park, NY, USA.
Brett A DolezalAirway and UC Fit Digital Health-Exercise Physiology Research Laboratory, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study investigated the acute effects of thoracic-spinal elevation, applied via a novel Bench Press Assist Device (BPAD), on pectoralis major activation and barbell kinetics during submaximal bench pressing. Ten resistance-trained males (23 ± 3 y) completed a randomized, single-blind, crossover trial performing five repetitions at 70 % 1-RM under standard flat bench and BPAD conditions. Bilateral surface electromyography (sEMG) assessed pectoralis major activation, while a linear position transducer recorded mean and peak barbell velocity, concentric power, and range of motion (ROM). Compared with the flat-bench condition, the BPAD produced significant increases in mean and peak velocity, bilateral pectoralis major activation (all p < 0.001), and ROM (p = 0.005). Concentric power rose by approximately 9 % but did not reach statistical significance, likely reflecting the fixed external load and the force-velocity trade-off at submaximal intensities. The observed gains in velocity and muscle activation indicate that thoracic elevation enhances mechanical efficiency and neuromuscular engagement during pressing without altering load demands. By facilitating thoracic extension and scapular retraction, the BPAD may improve length-tension relationships and joint alignment, yielding a smoother bar path and greater bilateral muscle symmetry. These findings highlight posture-focused interventions as a simple means to refine pressing mechanics, increase movement efficiency, and potentially reduce shoulder stress, likely driven by improved scapulothoracic mechanics and neural coordination. Future research should examine chronic adaptations to repeated use of thoracic elevation and its applicability across sexes, training levels, and varied load intensities.

Indexed as

Bench press biomechanicsneuromuscular activationposture optimizationsurface electromyographythoracic elevation

Identifiers

PMID42003891
PMCPMC13075562

What OpenQuestion holds

Textmetadata
LicenceCC BY-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.