Evidence map›Paper›PMID 41998677›Full record

Observational studyScandinavian journal of trauma, resuscitation and emergency medicine2026

Chest X-Ray evaluation using GPT for tube thoracostomy or conservative care in non-tension spontaneous pneumothorax.

Ertuğ Günsoy, Ahmet Aykut, Cem Yıldırım, Mehmet Veysel Öncül, Saim Türkoğlu

Abstract readObservational Study
In one paragraph

Observational study in Scandinavian journal of trauma, resuscitation and emergency medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ertuğ GünsoyEmergency Department, Van Education and Research Hospital, Van, Turkey. gunsoyertug@gmail.com.ORCID http://orcid.org/0000-0002-9653-3236
Ahmet AykutEmergency Department, Van Education and Research Hospital, Van, Turkey.ORCID http://orcid.org/0009-0001-3173-8994
Cem YıldırımEmergency Department, Van Education and Research Hospital, Van, Turkey.ORCID http://orcid.org/0009-0004-5359-6335
Mehmet Veysel ÖncülEmergency Department, Van Education and Research Hospital, Van, Turkey.ORCID http://orcid.org/0000-0002-3865-8364
Saim TürkoğluFaculty of Medicine, Department of Radiology, Yuzuncu Yıl University, Van, Turkey.ORCID http://orcid.org/0000-0001-8247-2009

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

objectiveSpontaneous pneumothorax (SP) commonly presents to the emergency department (ED), and clinicians must rapidly decide between conservative care and tube thoracostomy. Most artificial intelligence tools focus on pneumothorax detection rather than quantitative size estimation and actionable management recommendations. We aimed to evaluate whether a vision-enabled generative pre-trained transformer (GPT) model could estimate apical SP depth on chest radiographs (CXRs) and predict initial ED management.

methodsWe conducted a single-center retrospective observational study of adult patients (≥ 18 years) with confirmed SP on pre-intervention posteroanterior CXR (January 1, 2023-December 31, 2025). GPT received only the CXR plus age and sex and returned laterality, estimated apical depth (Depth_cm), and a binary management recommendation (tube thoracostomy vs conservative). The reference outcome was tube thoracostomy within 24 h. We calculated diagnostic performance metrics and area under the receiver operating characteristic curve (AUC). We assessed agreement between GPT depth estimates and blinded radiologist measurements using intraclass correlation coefficient (ICC), Bland-Altman analysis, and mean absolute error (MAE).

resultsAmong 101 patients, mean age was 33.1 ± 14.6 years and 89 (88.1%) were male; 53 (52.5%) underwent tube thoracostomy within 24 h. GPT showed sensitivity 86.8% (95% CI, 75.2%-93.5%), specificity 93.8% (95% CI, 83.2%-97.9%), and accuracy 90.1% (95% CI, 82.7%-94.5%), with Cohen's κ = 0.80 and AUC 0.90 (95% CI, 0.84-0.96). Depth agreement was strong (ICC, 0.893), with MAE 0.69 cm and mean bias -0.51 cm (95% limits of agreement, - 2.30 to 1.27 cm).

conclusionsIn confirmed SP, a vision-enabled GPT model produced apical depth estimates that closely agreed with radiologist measurements and generated management recommendations that substantially matched real-world ED decisions, supporting its potential role as adjunct imaging decision support.

Indexed as

Conservative TreatmentPneumothoraxRadiography, ThoracicThoracostomyAdultChest TubesFemaleGenerative Artificial IntelligenceHumansMaleMiddle AgedRetrospective StudiesChatGPTChest radiographyLarge language modelsSpontaneous pneumothoraxTube thoracostomy

Identifiers

PMID41998677
PMCPMC13214241

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.