Evidence map›Paper›PMID 41998629›Full record

ArticleBMC surgery2026

Biomechanical comparison of frame configuration screw fixation and conventional plate fixation for Sanders type iii fractures: a finite element analysis.

Miao Li, Boyu Zhang, Xiaodong Bai, Dawei Song, Baojun Wang, Wentao Chen

Abstract readComparative Study
In one paragraph

Article in BMC surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Miao LiDepartment of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China.
Boyu ZhangDepartment of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China.
Xiaodong BaiDepartment of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China.
Dawei SongDepartment of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China.
Baojun WangDepartment of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China. wangbaojun@ccmu.edu.cn.
Wentao ChenDepartment of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China. vintau@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSanders type III calcaneal fractures typically require surgical intervention. While open reduction and internal fixation (ORIF) provides robust stabilisation, it is associated with a high incidence of surgical site complications. Closed reduction with percutaneous screw fixation (CRPF) presents a lower risk of complications, but consensus on the optimal screw configuration remains elusive. In this study, a novel frame configuration screw fixation (FCSF) method is proposed, and its biomechanical properties are compared with those of conventional plate fixation through finite element analysis.

methodsCT images of the calcaneus from a healthy volunteer were acquired. Software was used to construct Sanders type III calcaneal fracture models, an ORIF model, and two FCSF models. The material properties and contact modes were assigned. Forces of 350 N and 700 N were applied to compare the stress and displacement across the different models.

resultsUnder 350 N/700 N loads, the ORIF group exhibited peak implant stresses of 80.36 MPa/161.41 MPa, peak calcaneal fracture fragment stresses of 36.08 MPa/72.34 MPa, and peak calcaneal fracture fragment displacements of 0.5133 mm/1.0286 mm. Under identical loads, FCSF A and B exhibited peak internal plant stress values of 75.15 MPa/149.03 MPa and 85.92 MPa/170.79 MPa, respectively. The peak stress values in the calcaneal fracture fragment were 25.92 MPa/51.80 MPa and 30.39 MPa/60.86 MPa. The peak calcaneal fracture fragment displacements were 0.0896 mm/0.1788 mm and 0.1021 mm/0.2042 mm, respectively.

conclusionFCSF outcomes comparable to those of ORIF in the treatment of Sanders type III fractures were observed, indicating that FCSF provides sufficient biomechanical stability. The configuration with a transverse screw positioned above the inner and outer longitudinal screws is the more ideal fixation approach. This study offers biomechanical support for minimally invasive screw fixation of the calcaneus.

Indexed as

Bone PlatesBone ScrewsCalcaneusFracture Fixation, InternalFractures, BoneBiomechanical PhenomenaFinite Element AnalysisHumansStress, MechanicalTomography, X-Ray ComputedBiomechanicsCalcaneal fractureFinite element analysisInternal fixation

Identifiers

PMID41998629
PMCPMC13220491

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.