ArticlePhysiotherapy research international : the journal for researchers and clinicians in physical therapy2026

Validity and Reliability of a Laser Pointer Device to Assess Knee Proprioception in Healthy and Active Individuals.

Héctor González-Pons, Elena Muñoz-Gómez, Sara Mollà-Casanova, Noemí Moreno-Segura, Pilar Serra-Añó, Marta Inglés

Abstract readValidation Study
In one paragraph

Article in Physiotherapy research international : the journal for researchers and clinicians in physical therapy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Letter to Editor: Validity and Reliability of a Laser Pointer Device to Assess Knee Proprioception in Healthy and Active Individuals.Physiotherapy research international : the journal for researchers and clinicians in physical therapy · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Héctor González-PonsUBIC Research Group, Department of Physiotherapy, Faculty of Physiotherapy, Universitat de València, València, Spain.ORCID https://orcid.org/0009-0005-2710-9545
Elena Muñoz-GómezUBIC Research Group, Department of Physiotherapy, Faculty of Physiotherapy, Universitat de València, València, Spain.ORCID https://orcid.org/0000-0001-9137-1656
Sara Mollà-CasanovaUBIC Research Group, Department of Physiotherapy, Faculty of Physiotherapy, Universitat de València, València, Spain.
Noemí Moreno-SeguraUBIC Research Group, Department of Physiotherapy, Faculty of Physiotherapy, Universitat de València, València, Spain.
Pilar Serra-AñóUBIC Research Group, Department of Physiotherapy, Faculty of Physiotherapy, Universitat de València, València, Spain.ORCID https://orcid.org/0000-0002-0743-3445
Marta InglésUBIC Research Group, Department of Physiotherapy, Faculty of Physiotherapy, Universitat de València, València, Spain.

Funding

Generalitat Valenciana, Conselleria d'Innovació, Universitats, Ciència i Societat CIAICO/2021/215Generalitat Valenciana, Conselleria d'Innovació, Universitats, Ciència i Societat CIAICO/2024/107Ministerio de Universidades PID2021-125694OB-I00Ministry of Science, Innovation and Universities FPU23/01464
6 · The paper itself

Abstract

background and purposeKnee proprioception offers valuable information about the state of the knee joint. The most widely used protocol to estimate it is the joint position reproduction (JPR), although the validated instruments for its measurement are expensive and complex. The aim of this study was to estimate the validity and reliability of a laser pointer device to assess knee proprioception in healthy and active subjects.

methodsA descriptive cross-sectional study. The study was conducted at a Research Laboratory of the Faculty of Physiotherapy, University of Valencia (Spain). Twenty-five healthy and active individuals (mean (SD) age = 27.24 (3.93) years) were assessed. Proprioception measurements were evaluated with 15° and 50° knee flexion in closed kinetic chain (CKC) and open kinetic chain (OKC), respectively, using a laser device and also a digital inclinometer (to validate the first), on two days by two different evaluators.

resultsValidity analysis indicated a moderate to strong correlation between the laser pointer device and the digital inclinometer in all the tests (Pearson's correlation = 0.40-0.55 (CKC) and 0.54-0.82 (OCK)). In the OKC 50° knee test, a moderate inter-rater reliability (ICC = 0.54) and a strong intra-rater reliability (ICC = 0.65) was shown, and in the CKC 15° test a strong inter-rater reliability (ICC = 0.62) and moderate intra-rater reliability (ICC = 0.58) was shown. The rest of the tests showed no intra-rater and inter-rater reliability (ICC = 0.10-0.24). DISCUSSION: Though further research is needed, the results suggest that it could be considered as an affordable, simple and effective resource both in research and in clinical practice.

Indexed as

Knee JointLasersProprioceptionAdultCross-Sectional StudiesFemaleHumansMaleRange of Motion, ArticularReproducibility of ResultsYoung Adultjoint position reproductionkneelaserproprioception

Identifiers

PMID41995013
PMCPMC13088210

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked