Evidence map›Paper›PMID 41994324›Full record

ArticleEuropean journal of radiology open2026

Utility of breath-hold half-Fourier single-shot turbo spin-echo with deep learning-based reconstruction for acquiring fat-suppressed T2-weighted images of the pancreas.

Tomofumi Nonaka, Fumihito Ichinohe, Kazuki Oyama, Akira Yamada, Hayato Hayashihara, Yasuo Adachi, Yoshihiro Kito, Yusuke Kanki, Katsuya Maruyama, Marcel Dominik Nickel and 1 more

Abstract read
In one paragraph

Article in European journal of radiology open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Tomofumi NonakaDepartment of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan.
Fumihito IchinoheDepartment of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan.
Kazuki OyamaDepartment of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan.
Akira YamadaDepartment of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan.
Hayato HayashiharaRadiology Division, Shinshu University Hospital, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.
Yasuo AdachiRadiology Division, Shinshu University Hospital, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.
Yoshihiro KitoRadiology Division, Shinshu University Hospital, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.
Yusuke KankiMagnetic Resonance Department, Siemens Healthcare K.K., Gate City Osaki West Tower, 1-11-1 Osaki, Shinagawa, Tokyo 141-8644, Japan.
Katsuya MaruyamaMR Research & Collaboration Department, Siemens Healthcare K.K., Gate City Osaki West Tower, 1-11-1 Osaki, Shinagawa, Tokyo 141-8644, Japan.
Marcel Dominik NickelMR Application Predevelopment, Siemens Healthcare GmbH, Allee am Roethelheimpark 2, Erlangen 91052, Germany.
Yasunari FujinagaDepartment of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To determine the best technique for acquiring fat-suppressed T2-weighted images (FS-T2WI) of the pancreas, in terms of acquisition time and image quality, among conventional respiratory-gated turbo spin echo (RG-TSE), research breath-hold TSE with deep learning-based reconstruction (BH-DL-TSE), and research breath-hold half-Fourier single-shot turbo spin-echo with deep learning-based reconstruction (BH-DL-HASTE). Methods: Eighty-seven patients with suspected pancreatic diseases who underwent magnetic resonance imaging between April and May 2022 were evaluated. Sixty-four focal pancreatic lesions > 5 mm were also evaluated. FS-T2WI of the pancreas were acquired with 3-T scanners using RG-TSE, BH-DL-TSE, and BH-DL-HASTE. Two radiologists qualitatively evaluated image quality on a 5-point scale. We calculated the pancreas signal-to-noise ratio (SNR) and lesion-to-pancreas contrast-to-noise ratio (CNR). Friedman's test and Dunn's multiple comparisons test were performed to assess differences among the three techniques. Results: The mean acquisition time was 3 min 51 s (95 % confidence interval: 3 min and 37 s - 4 min and 6 s) for RG-TSE, 40 s for BH-DL-TSE, and 20 s for BH-DL-HASTE. BH-DL-HASTE provided the fewest artifacts and the sharpest edges (P < 0.0001), the most conspicuous main pancreatic duct (P = 0.0001 versus RG-TSE and P < 0.0001 versus BH-DL-TSE), and more conspicuous lesions than those in BH-DL-TSE (P = 0.0028). There was no significant difference in the SNR (P = 0.0766). RG-TSE and BH-DL-HASTE provided a higher CNR than BH-DL-TSE (P = 0.0018 and P = 0.0026, respectively). Conclusions: BH-DL-HASTE would be better than RG-TSE and BH-DL-TSE for acquiring FS-T2WI of the pancreas.

Indexed as

Deep learningHalf-Fourier single-shot turbo spin-echoPancreasReconstructionT2-weighted imageTurbo spin-echo

Identifiers

PMID41994324
PMCPMC13080395

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.