Evidence map›Paper›PMID 41993891›Full record

ArticleOphthalmology science2026

Predictions of Through-Focus Performance of Presbyopia-Correcting Intraocular Lenses in Presbyopic Subjects Using a Visual Simulator.

Petros Papadogiannis, Xoana Barcala, Irene Siso-Fuertes, Amal Zaytouny, Lucie Sawides, Carlos Dorronsoro, Susana Marcos

Abstract read
In one paragraph

Article in Ophthalmology science, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Petros Papadogiannis2EyesVision S.L., Madrid, Spain.
Xoana Barcala2EyesVision S.L., Madrid, Spain.
Irene Siso-Fuertes2EyesVision S.L., Madrid, Spain.
Amal ZaytounyInstitute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain.
Lucie Sawides2EyesVision S.L., Madrid, Spain.
Carlos Dorronsoro2EyesVision S.L., Madrid, Spain.
Susana MarcosCenter for Visual Science, The Institute of Optics, Flaum Eye Institute, University of Rochester, New York.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To validate whether visual simulations of multifocal intraocular lenses and extended depth of focus (EDOF) intraocular lenses (IOLs) in phakic presbyopes replicate postoperative vision, and to compare performance across these lenses in the same subject. Design: A cross-sectional study; evaluation of technology. Subjects: Twenty-three presbyopes with clear crystalline lenses were evaluated binocularly using SimVis Gekko visual simulator (2EyesVision). Methods: Six commercial multifocal and EDOF IOLs were simulated using the principle of temporal multiplexing: AcrySoft IQ PanOptix, FineVision POD F, AT Lisa tri, Tecnis Symfony, AcrySoft IQ Vivity, and AT Lara. Defocus visual acuity (DFVA) curves were measured for each simulated IOL under photopic conditions. Simulated IOLs were programmed from published through-focus modulation transfer function data at 15 cycles/degree. Defocus visual acuity curves through simulated IOLs were compared to average postoperative DFVA data from peer-reviewed publications (108-322 pseudophakic patients per IOL). Main Outcome Measures: Cross-correlation, root mean square error (RMSE), depth of focus (DOF), and relative visual benefit/degradation at far, intermediate, and near distances. Results: Simulated IOLs accurately reproduced on-bench optical profiles in terms of through-focus Visual Strehl Ratio (cross-correlation >0.98, RMSE <0.04). Defocus visual acuity curves through simulated IOLs closely matched postoperative curves in subjects implanted with the corresponding IOL (cross-correlation ≥0.94, RMSE ≤0.07), with far vision differences ≤0.09 logarithm of the minimum angle of resolution (logMAR). Discrepancies were largest at high near vergences (up to 0.17 logMAR). Trifocal IOLs (PanOptix, FineVision, AT Lisa) expanded DOF by ∼1.5 D compared with monofocal IOLs, while EDOF IOLs (Symfony, Vivity, AT Lara) expanded DOF by ∼0.7 D. Visual simulations replicated relative gains at intermediate/near and degradations at far, consistent with clinical outcomes in implanted patients. Intersubject variability observed in simulations mirrored that reported postoperatively. Conclusions: The SimVis Gekko visual simulator reproduces, in a simulated preimplantation context, the reported postoperative visual performance, both with multifocal and EDOF IOLs, capturing both group-level and subject-specific variability. The results suggest that this tool can provide patients with a representative preview of relative visual performance of different IOLs prior to surgery. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Indexed as

Extended depth of focus intraocular lenses (EDOFs)Multifocal intraocular lenses (MIOLs)Preoperative predictionSubject-specific visual outcomesVisual simulation

Identifiers

PMID41993891
PMCPMC13081673

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.