Evidence map›Paper›PMID 41989728›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2026

Esophageal heating characteristics of very high-power short duration radiofrequency ablation in a myocardial phantom model.

Shayekh Abedin, Xingzhou Liu, Amir H Pour, Michael A Barry, Stuart P Thomas, Pierre C Qian

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shayekh Abedin *Department of Cardiology, Westmead Hospital, Cnr of Hawkesbury and Darcy Road, Westmead, Sydney, NSW, 2145, Australia.
Xingzhou Liu *Department of Cardiology, Westmead Hospital, Cnr of Hawkesbury and Darcy Road, Westmead, Sydney, NSW, 2145, Australia.
Amir H PourDepartment of Cardiology, Westmead Hospital, Cnr of Hawkesbury and Darcy Road, Westmead, Sydney, NSW, 2145, Australia.
Michael A BarryDepartment of Cardiology, Westmead Hospital, Cnr of Hawkesbury and Darcy Road, Westmead, Sydney, NSW, 2145, Australia.
Stuart P ThomasDepartment of Cardiology, Westmead Hospital, Cnr of Hawkesbury and Darcy Road, Westmead, Sydney, NSW, 2145, Australia.
Pierre C QianDepartment of Cardiology, Westmead Hospital, Cnr of Hawkesbury and Darcy Road, Westmead, Sydney, NSW, 2145, Australia. pierre.qian@sydney.edu.au.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundVery high short duration radiofrequency catheter ablation can rapidly achieve pulmonary vein isolation, however safety to the esophagus during posterior left atrial ablation is uncertain. This study looked to characterise lesion formation and esophageal thermal effects with very high-power short duration (vHPSD), and to compare it with high power short duration (HPSD) and low power long duration (LPLD) radiofrequency ablation, using esophageal heating and esophageal temperature probe (ETP) measurements.

methodsA thermochromic gel phantom model of posterior left atrial wall with an embedded ETP was used to assess heating kinetics during radiofrequency ablation (RFA). RFA was performed at 30W/20s (LPLD), 50W/5s (HPSD), 90W/3 and 90W/4s (vHPSD). Continuous ETP temperature was recorded, and thermal mapping of esophageal temperature was performed.

results90W/3s (5.17 ± 0.01 mm) and 90W/4s (5.62 ± 0.06 mm) produced broader lesions than 50W/5s (4.17 ± 0.11 mm, p < 0.0001) and 30W/20 s (3.95 ± 0.38 mm, p < 0.01), with similar depth. The ETP underestimated the peak esophageal temperature across all ablation settings with the highest temperature disparity in 30W/20s (3.70 ± 0.60 °C, p = 0.0007), 90W/3s (2.87 ± 0.06 °C, p < 0.0001) and 90W/4s (2.53 ± 0.25 °C, p = 0.0016) groups. Thermal latency was greatest in 90W/4s, followed by 90W/3s, 50W/5s and 30W/20s. Consecutive applications of RFA energy led to heat accumulation and greater esophageal heating, most marked with 90W/4s (41.13 ± 0.12 °C), and 30W/20s (40.90 ± 0.10 °C).

conclusionvHPSD produces broader lesions with comparable depth which may result in improved PVI lesion contiguity, however, repeated successive applications with vHPSD may lead to greater esophageal heating and inaccurate ETP monitoring due to temperature disparities and thermal latency.

Indexed as

Ablation biophysicsAtrial fibrillationEsophageal injuryEsophageal temperatureRadiofrequency ablationVery high power short duration

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.