Evidence map›Paper›PMID 41988331›Full record

ReviewOTO open

Does Electrical Stimulation Therapy Influence Synkinesis in Facial Paralysis? A Systematic Review.

Hänel W Eberly, Marly Aziz, F Jeffrey Lorenz, Heather K Schopper, Jessyka G Lighthall

Abstract readReview
In one paragraph

Review in OTO open. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hänel W EberlyDivision of Otolaryngology-Head and Neck Surgery Yale University School of Medicine New Haven Connecticut USA.ORCID https://orcid.org/0000-0003-2043-7413
Marly AzizPenn State College of Medicine Hershey Pennsylvania USA.
F Jeffrey LorenzDepartment of Otolaryngology-Head and Neck Surgery Penn State Milton S. Hershey Medical Center and Penn State College of Medicine Hershey Pennsylvania USA.ORCID https://orcid.org/0000-0001-5902-7054
Heather K SchopperDepartment of Otolaryngology-Head and Neck Surgery Penn State Milton S. Hershey Medical Center and Penn State College of Medicine Hershey Pennsylvania USA.ORCID https://orcid.org/0000-0002-4549-5145
Jessyka G LighthallDepartment of Otolaryngology-Head and Neck Surgery Penn State Milton S. Hershey Medical Center and Penn State College of Medicine Hershey Pennsylvania USA.ORCID https://orcid.org/0000-0002-8500-5059

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Facial paralysis (FP) has aesthetic, social, and functional consequences. While electrical stimulation (ES) shows promise for peripheral nerve injury, its role in FP remains controversial due to concerns about increasing synkinesis. Data Sources: A literature review was conducted using Medline/PubMed, Cochrane, and Web of Science databases. Review Methods: Included studies evaluated the incidence or severity of synkinesis after ES in FP patients. Extracted data included demographics, ES parameters, FP etiology, synkinesis outcomes, and treatment duration. Results: Of 601 identified articles, 6 met inclusion criteria, comprising 243 patients (92 female, reported in 5 studies). Bell's palsy was the most common FP etiology (76.5%), followed by iatrogenic facial nerve injury (20.2%). Time to treatment ranged from 1 week to 7 years post-onset. Treatment durations varied from 2 weeks to 29 months, with inter-impulse gaps of 30 to 3000 milliseconds, phase durations of 10 to 700 milliseconds, and amplitudes of 0.5 to 27 mA. All ES was transcutaneous. Three of 5 studies reported no differences in synkinesis scores between ES and control groups. Two studies found no differences in synkinesis incidence. Only one study showed reduced synkinesis in the ES group. Conclusions: This study represents an up-to-date review of synkinesis in FP patients receiving ES. Evidence suggests a benefit in overall facial function for patients without significant additional risk of synkinesis. Inconsistencies in synkinesis outcomes and measurement underscore the need for further research in this area.

Indexed as

electrical stimulationfacial paralysissynkinesis

Identifiers

PMID41988331
PMCPMC13078372

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.