Evidence map›Paper›PMID 41983330›Full record

ArticleAdvanced materials (Deerfield Beach, Fla.)2026

Flexible Dielectric Acoustic Resonator Patch for Tissue Regeneration.

Donyoung Kang, Byeongseok Ryu, Sujeong Ahn, Junhyub Kim, Myeonghun Jang, Jeong Ho Cho, Won-Gun Koh, Hyungsuk Lee

Abstract read
In one paragraph

Article in Advanced materials (Deerfield Beach, Fla.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Donyoung KangSchool of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-2680-7489
Byeongseok RyuDepartment of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea.ORCID https://orcid.org/0009-0005-5329-2216
Sujeong AhnDepartment of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea.
Junhyub KimSchool of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea.
Myeonghun JangDepartment of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea.ORCID https://orcid.org/0009-0002-7542-541X
Jeong Ho ChoDepartment of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-1030-9920
Won-Gun KohDepartment of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-5191-2531
Hyungsuk LeeSchool of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-7873-7163

Funding

Commercialization Promotion Agency for R&D Outcomes RS-2026-25532857Ministry of Science and ICT, South Korea RS-2021-NR059302Ministry of Science and ICT, South Korea RS-2024-00432946Ministry of Science and ICT, South Korea RS-2024-00449435Ministry of Science and ICT, South Korea RS-2025-18362970National Research Foundation of Korea
6 · The paper itself

Abstract

Ultrasound (US) therapy offers a non-invasive means of stimulating cellular activity, promoting tissue regeneration, and wound healing. However, current US transducers based on piezoelectric ceramics are rigid, mechanically incompatible with soft tissues, and thus unsuitable for wearable applications. To overcome these limitations, we developed dielectric patches that generate high-frequency acoustic waves using electrostatic resonance between interdigitated electrodes and a flexible polymer substrate. We identified the resonance frequency by analyzing the streaming motion of a droplet placed on the device surface while sweeping the frequency of the applied voltage. We fabricated a dielectric acoustic resonator patch (DARP) exhibiting acoustic resonance at 20 MHz by regulating IDE spacing and substrate thickness. The developed DARP maintained >95% of its acoustic output in the bending tests with 300 cycles regardless of the bending direction. The polyimide-based device exhibited ∼50% optical transmittance, which is beneficial for in situ imaging. Wound healing assays revealed that the migration speed of fibroblasts increased by 1.5-fold after 5 min of DARP stimulation. We also demonstrated that DARP was able to deliver acoustic energy into tissue-mimicking hydrogels with curved and planar surfaces. DARP can be applied to develop a platform for ultrasound-mediated wearable medical devices and regenerative therapies.

Indexed as

AcousticsRegenerationAnimalsCell MovementElectrodesFibroblastsHumansHydrogelsMiceWound HealingHydrogelsdielectric elastomer actuatorultrasoundwearable electronicswound healing

Identifiers

PMID41983330
PMCPMC13432006

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.