Evidence map›Paper›PMID 41982581›Full record

ArticleCureus2026

An Analysis of the Correlation Between Component Placement and Functional Outcomes by Using Orthoscanogram in Primary Total Knee Arthroplasty.

Harish Dv, Raviraj Tantry, Amarnath Dasari, Aravind Devendrappa, Sravya Kotha, Mohammed Shahid

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Harish DvOrthopaedics, Vydehi Institute of Medical Sciences and Research Centre, Bengaluru, IND.
Raviraj TantryOrthopaedics and Traumatology, Vydehi Institute of Medical Sciences and Research Centre, Bengaluru, IND.
Amarnath DasariOrthopaedics, Vydehi Institute of Medical Sciences and Research Centre, Bengaluru, IND.
Aravind DevendrappaOrthopaedic Surgery, Vydehi Institute of Medical Sciences and Research Centre, Bengaluru, IND.
Sravya KothaOrthopaedic Surgery, Vydehi Institute of Medical Sciences and Research Centre, Bengaluru, IND.
Mohammed ShahidOrthopaedics, Vydehi Institute of Medical Sciences and Research Centre, Bengaluru, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Total knee arthroplasty (TKA) is a well-established surgical treatment for advanced knee osteoarthritis, with the goals of relieving pain, restoring function, and improving the patient's quality of life. Accurate alignment and optimal component placement are key determinants of implant longevity and postoperative functional outcomes following TKA. Restoration of the neutral mechanical axis of the lower limb is thought to minimize abnormal stresses on the prosthesis and surrounding bone. An orthoscanogram provides an accurate and reliable method for assessing the mechanical axis and overall axial alignment of the lower extremity. This study aimed to evaluate the correlation between component placement, assessed using orthoscanogram, and functional outcomes following primary TKA. Methodology This was a hospital-based comparative study conducted at Vydehi Institute of Medical Sciences and Research Centre, Bengaluru. A total of 60 patients with primary knee osteoarthritis who underwent primary TKA were included based on predefined inclusion and exclusion criteria. Full-length standing orthoscanograms were obtained preoperatively and postoperatively to assess mechanical axis alignment and component positioning using tibial zone classification. Functional outcomes were evaluated using the Knee Society Clinical Score (KSCS) and Knee Society Functional Score (KSFS) at a minimum follow-up of six months. Statistical analysis was performed to assess the association between mechanical axis alignment and functional outcomes. Results Postoperative orthoscanogram analysis demonstrated that patients in whom the mechanical axis passed through Zone 2 and the central (Zone C) of the tibial plateau showed significantly superior functional outcomes. According to the KSCS, the majority of patients achieved excellent to good results. Similarly, KSFS showed marked improvement postoperatively, particularly in patients with near-neutral mechanical alignment. A positive correlation was observed between optimal component placement, restoration of the mechanical axis, and improved functional outcome. Conclusions Accurate restoration of the mechanical axis and optimal component placement in primary TKA significantly influence postoperative functional outcomes. Orthoscanogram is a valuable and reliable tool for assessing lower limb alignment and component positioning. Postoperative mechanical axis passing through Zone 2 and the central zone is associated with excellent functional results. Emphasis on precise alignment during TKA can enhance patient satisfaction and potentially improve implant longevity.

Indexed as

component placementfunctional outcomeknee society scoremechanical axisorthoscanogramtotal knee arthroplasty

Identifiers

PMID41982581
PMCPMC13071522

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked