Evidence map›Paper›PMID 41979721›Full record

ArticleMedical & biological engineering & computing2026

An automated method for precise definition of fracture reduction targets.

Yifei Wang, Chuanba Liu, Zhongyu Liu, Boyu Yang, Yuhui Wang, Tao Sun

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yifei WangKey Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, 300354, China.
Chuanba LiuKey Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, 300354, China. liuchuanba@tju.edu.cn.ORCID http://orcid.org/0000-0002-7696-7408
Zhongyu LiuDepartment of Surgery, Tianjin Hospital, Tianjin, China.
Boyu YangKey Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, 300354, China.
Yuhui WangKey Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, 300354, China.
Tao SunKey Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, 300354, China.

Funding

Guizhou Provincial Science and Technology Support Project 2025-136Tianjin Natural Science Foundation Project 22JCJQJC00050Tianjin Natural Science Foundation Project 24JCQNJC01360
6 · The paper itself

Abstract

Anatomical reduction is essential for the treatment of long bone fractures, while well-defined reduction targets are critical for ensuring reliable outcomes. However, due to the subjective nature of physician experience and the structural deficiencies often found in imaging data, the efficient and high-quality definition of reduction targets remains a significant challenge. This paper proposes a feature dynamic fusion network model (FDF-Net) for target definition. FDF-Net adopts a dual-branch heterogeneous encoding-joint decoding architecture to construct an intelligent prediction system with bone structure perception capabilities. Through a feature fusion mechanism guided by skeletal repositioning prior knowledge, combined with geometry-enhanced point cloud feature encoding, and utilizing decoupled dual prediction heads for explicit modeling of rigid body transformation physical constraints, the model achieves precise mapping from raw point clouds to repositioning parameters. Comparative experiments against state-of-the-art neural network models demonstrated that FDF-Net achieved superior performance. On the simulated dataset, the model attained mean errors of 0.653 ± 0.387 mm in translation and 0.560 ± 0.301° in rotation. On the clinical dataset, the corresponding errors were 1.934 ± 1.146 mm and 0.829 ± 0.386°. FDF-Net enables precise and robust definition of reduction targets and demonstrates potential for translation into clinical practice.

Indexed as

Fractures, BoneAlgorithmsHumansNeural Networks, ComputerFeature extractionFeature fusion.Long bone fracturesReduction target definition

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.