A Novel Contactless Scanning Conductivity-Detection Approach for Moving Reaction Boundary Analysis in Electrophoresis Titration Sensors.

Haozheng Dai, Youli Tian, Ke-Er Chen, Weiwen Liu, Qiang Zhang, Chengxi Cao

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Haozheng DaiSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.
Youli TianSchool of Artificial Intelligence in Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
Ke-Er ChenSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0009-0003-0837-7558
Weiwen LiuSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0002-2603-2815
Qiang ZhangSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.
Chengxi CaoSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0002-3873-5112

Funding

National Biological Medicine Technology Innovation Center "open competition mechanism to select the best candidates" technology research project NCTIB2023XB03002National Natural Science Foundation of China 22104082National Natural Science Foundation of China 22574099National Natural Science Foundation of China 32175034National Natural Science Foundation of China 3247120634Postdoctoral Fellowship Program of CPSF GZC20241027
6 · The paper itself

Abstract

Electrophoresis titration sensors are widely used for biomarker detection. However, traditional methods rely on a visible boundary for signal readout. Although conventional capacitively coupled contactless conductivity detection avoids indicator dependence, its single-point detection method suffers from long measurement times, large amounts of redundant data, and the inability to dynamically monitor the moving reaction boundary. To address these issues, we developed a novel contactless scanning capacitively coupled conductivity-detection method for microchip electrophoretic titration sensors. This method enables the rapid tracking and monitoring of the boundary within the microfluidic channel through dynamic scanning. The spatial distribution of conductivity during electrophoretic titration was theoretically analyzed. To evaluate the method, glucose was chosen as a model analyte. Quantitative detection was achieved over the linear range of 0.2-50 mM, with the limit of detection of 0.1 mM. The method exhibited satisfactory stability with relative standard deviation values ranging from 0.9% to 4.3% (

Indexed as

Biosensing TechniquesElectric ConductivityElectrophoresisElectrophoresis, MicrochipGlucoseGlucoseelectrophoresis titrationmoving reaction boundaryscanning contactless conductivity detection

Identifiers

PMID41978047
PMCPMC13075292

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.