Evidence map›Paper›PMID 41977953›Full record

ArticleSensors (Basel, Switzerland)2026

Urban Water Leakage Detection System over Dark Fiber Networks Based on Distributed Acoustic Sensing and Sparse Autoencoders.

Vahid Sharif, Yuanyuan Yao, Alayn Loayssa, Mikel Sagues

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Vahid SharifInstitute of Smart Cities, Department of Electrical, Electronic and Communications Engineering, Universidad Pública de Navarra, Campus de Arrosadia, 31006 Pamplona, Spain.ORCID 0000-0002-7485-8240
Yuanyuan YaoCollege of Engineering and Applied Sciences, Nanjing University, Nanjing 210023, China.
Alayn LoayssaInstitute of Smart Cities, Department of Electrical, Electronic and Communications Engineering, Universidad Pública de Navarra, Campus de Arrosadia, 31006 Pamplona, Spain.ORCID 0000-0002-6502-6135
Mikel SaguesInstitute of Smart Cities, Department of Electrical, Electronic and Communications Engineering, Universidad Pública de Navarra, Campus de Arrosadia, 31006 Pamplona, Spain.ORCID 0000-0003-3648-1507

Funding

China Scholarship CouncilERDF A way to make EuropeMinisterio de Ciencia e Innovación (Spain) PID2022-137269OB-C21
6 · The paper itself

Abstract

We propose and experimentally validate an automatic urban water leakage detection architecture that leverages dark fiber links already deployed in telecommunication networks in underground conduits in the vicinity of water pipelines. The sensing stage relies on a differential-phase coherent optical time-domain reflectometry interrogator enhanced with optical pulse compression to improve sensitivity. Building on this vibration acquisition stage, automatic leakage detection algorithms are implemented by searching for leak-induced activity in the frequency domain, which is well suited to revealing leakage-related features. After acquiring a baseline calibration to characterize normal-condition vibrations at each sensing position, leakage candidates are identified by comparing distribution-based metrics computed over multiple measurements against the corresponding baseline statistics. Two automatic leakage detection strategies are developed. First, low-complexity feature-based metrics are implemented, enabling continuous monitoring with minimal computational requirements. Second, an autoencoder-based anomaly detection technique is introduced, which also relies on location-specific normal-condition calibration but reduces the dependence on prior knowledge of the expected leakage vibration signatures. A real-world field trial on an urban network demonstrates reliable detection and localization using controlled leak events generated in the field, with measurements performed over a 17 km sensing fiber and an effective spatial resolution of 2.6 m. Benchmarking against a commercial punctual electro-acoustic leak detector yields consistent trends. Overall, the proposed system could complement existing technologies by enabling automated, continuous city-scale monitoring over already deployed dark fiber infrastructure.

Indexed as

anomaly detectiondark fiberdistributed acoustic sensingleakage detectionoptical pulse compressionurban water networks

Identifiers

PMID41977953
PMCPMC13075247

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.