ArticleSensors (Basel, Switzerland)2026
Data-Driven Material Selection for Flexible Wearable Sensors Under Environmental Coupling Conditions.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Flexible wearable electronics have shown strong potential for medical and health monitoring; however, conventional materials often fail to simultaneously satisfy the requirements of signal stability, wear comfort, and environmental adaptability under dynamic use conditions. To address this issue, this study proposes a data-driven material selection framework for flexible wearable sensors based on the extreme gradient boosting (XGBoost) algorithm. The model integrates user perception, material physical parameters, and environmental coupling performance indicators to enable intelligent material matching and recommendation. Experimental results show that the proposed model achieves a recommendation accuracy of 94.5%, outperforming conventional comparison methods. Among the candidate materials, silver nanowires (AgNWs) exhibit superior overall performance, including a higher signal-to-noise ratio, lower skin-contact impedance, and stronger sweat resistance. In physiological monitoring experiments, the maximum deviation of the sensor response was below 3% under both static and motion conditions. In environmental coupling tests, the recommended material improved the system signal-to-noise ratio by 68% and reduced 24-h sensitivity decay by 75%. These results indicate that the proposed XGBoost-based framework can effectively support material selection for flexible wearable sensors and improve signal reliability and environmental adaptability in complex application scenarios.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.