ArticleSensors (Basel, Switzerland)2026
Ultrasonic Testing of Laser Welds in Medium-Thick Titanium Alloy Plates.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
To address the challenge of detecting internal defects in medium-thick titanium alloy laser welds, a combined simulation and experimental study on ultrasonic testing was conducted. A finite element model employing a 5 MHz shear wave angle transducer for inspecting titanium alloy welds was established. An ultrasonic testing system was developed, incorporating a DPR300 pulser-receiver (JSR Ultrasonics, Pittsford, NY, USA) and an MSO5204 oscilloscope (RIGOL, Suzhou, China), and was calibrated using standard reference blocks. The inspection results for four prefabricated internal defects at various depths demonstrated that all defects were effectively detected, with the minimum detectable equivalent defect size reaching 1 mm. The measured signal-to-noise ratio (SNR) averaged 17.6 dB, validating the high sensitivity of the proposed system. The mean absolute error for defect localization was 0.438 mm, achieving a positioning accuracy better than 0.5 mm. This study indicates that the pro-posed method enables effective detection and accurate localization of internal defects in titanium alloy laser welds, providing critical technical support for laser welding quality assessment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.