Evidence map›Paper›PMID 41977838›Full record

ArticleSensors (Basel, Switzerland)2026

A Novel System for Physiological Signal Monitoring and Health-Informed Electrotactile Feedback for First Responders.

Bojan Jorgovanović, Vojin Ilić, Nikola Jorgovanović, Marina Peña-Díaz, Goran Bijelić, Jovana Malešević, Miloš Kostić, Matija Štrbac

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Bojan JorgovanovićFaculty of Technical Sciences, University of Novi Sad, 21000 Novi Sad, Serbia.ORCID 0000-0002-8934-3928
Vojin IlićFaculty of Technical Sciences, University of Novi Sad, 21000 Novi Sad, Serbia.ORCID 0000-0002-4528-8832
Nikola JorgovanovićFaculty of Technical Sciences, University of Novi Sad, 21000 Novi Sad, Serbia.ORCID 0000-0001-9466-2969
Marina Peña-DíazTecnalia, Basque Research and Technology Alliance (BRTA), 20009 Donostia-San Sebastian, Spain.ORCID 0000-0001-9309-6272
Goran BijelićTecnalia, Basque Research and Technology Alliance (BRTA), 20009 Donostia-San Sebastian, Spain.
Jovana MaleševićTecnalia Serbia Ltd., 11000 Belgrade, Serbia.ORCID 0000-0002-4487-9999
Miloš KostićTecnalia Serbia Ltd., 11000 Belgrade, Serbia.ORCID 0000-0003-1299-4252
Matija ŠtrbacTecnalia Serbia Ltd., 11000 Belgrade, Serbia.ORCID 0000-0002-6831-1943

Funding

European Union 450 HORIZON-WIDERA-2023-ACCESS-04 101159927European Union H2020 883315
6 · The paper itself

Abstract

Ensuring the safety and effectiveness of first responder teams during critical missions requires real-time health monitoring and responsive intervention systems. This study presents a novel system comprising a multimodal wearable device integrated with a remote command centre, designed to support the physiological monitoring and guidance of first responders in the field. The wearable device includes three main components: a physiological and biochemical signal acquisition unit, an electrotactile stimulation unit and a powerful communication interface. The acquisition unit continuously samples heart rate, body temperature, and biochemical markers from sweat, transmitting this data wirelessly to the remote command centre. The transmitted physiological data could be analyzed at the command centre and, based on the inferred first responder condition, appropriate feedback commands could be issued back to the corresponding wearer. The commands are then executed by the electrotactile stimulation unit on the wearable device. Initial testing in laboratory settings confirmed the system's ability to generate accurate electrochemical readings and dehydration assessment through changes in bulk ionic conductivity. Electrochemical impedance spectroscopy showed good agreement with a commercial potentiostat. Heart rate and temperature readings demonstrated satisfying accuracy with minor removable artifacts. Field trials with first responders validated continuous signal transmission and electrotactile feedback with over 80% success. These results confirm the system's robustness and modularity, supporting its application in operational environments.

Indexed as

Wearable Electronic DevicesBody TemperatureFeedbackHeart RateHumansMonitoring, PhysiologicTouchclosed-loop biofeedbackelectrotactile stimulation feedbackmultimodal bio-sensingphysiological signal acquisitionreal-time monitoringwearable biosensors

Identifiers

PMID41977838
PMCPMC13074422

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.