Evidence map›Paper›PMID 41977805›Full record

ArticleSensors (Basel, Switzerland)2026

Development and Phantom Validation of a Small-Form-Factor SWIR Emitter Probe for Hydration-Sensitive Spatial-Ratio Measurements in Gelatin-Intralipid Phantoms.

Georgei Farouq, Devang Vyas, Amir Tofghi Zavareh

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Georgei FarouqDepartment of Engineering Technology and Industrial Distribution, Texas A&M University, College Station, TX 77843, USA.
Devang VyasDepartment of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.ORCID 0009-0007-6887-9882
Amir Tofghi ZavarehDepartment of Engineering Technology and Industrial Distribution, Texas A&M University, College Station, TX 77843, USA.ORCID 0000-0001-6602-8725

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Non-invasive assessment of tissue water content is clinically relevant for edema detection, fluid management, and monitoring of local inflammation. In the short-wave infrared (SWIR), water exhibits strong absorption near 1450 nm with a secondary band near 1650 nm, enabling hydration-sensitive reflectance measurements. However, many SWIR systems rely on spectrometers or high-power broadband sources, limiting translation to compact or wearable platforms. We present a compact SWIR diffuse-reflectance probe built from small-form-factor components using four discrete LEDs (1450 nm and 1650 nm) and a single photodetector to acquire spatially resolved measurements at two source-detector separations (4.5 mm and 7 mm). Probe-geometry-matched Monte Carlo simulations were used to generate lookup tables relating reduced scattering to same-wavelength spatial ratios. A diffusion-based forward model was then used to perform a calibration-anchored water-fraction consistency analysis. Eight gelatin-Intralipid phantoms spanning two scattering conditions and formulation-defined water fractions were evaluated. Spatial-ratio signatures were repeatable and monotonic with nominal water fraction, yielding a mean absolute percent error of 1.55% and a maximum absolute percent error of 3.33% under absorption-consistent conditions. These results demonstrate the feasibility of compact SWIR ratio sensing for controlled hydration changes in tissue-mimicking phantoms and provide a modeling framework for future extension to unknown or in vivo samples.

Indexed as

GelatinPhantoms, ImagingWaterEmulsionsMonte Carlo MethodSpectrophotometry, InfraredEmulsionsGelatinWaterdiffuse reflectancegelatin–Intralipid phantomhydration sensingMonte Carlo lookup tablesshort-wave infrared spectroscopy (SWIRS)small-form-factor sensorspatially resolved spectroscopy

Identifiers

PMID41977805
PMCPMC13074628

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked