Evidence map›Paper›PMID 41977544›Full record

ArticlePolymers2026

Automated Installation System for Joint Casing with Circumferential Temperature Control in District Heating Pipelines Using a Heat-Shrinkable PEX Tube.

Seungbeom Jang, Yuhyeong Jeong, Youngjin Jeon, Hyungsu Ju, Jooyong Kim, Yeonsoo Kim, Junghae Hwang, Dongil Choi, Jonghun Yoon

Abstract read
In one paragraph

Article in Polymers, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Seungbeom JangDepartment of Mechanical Engineering, Hanyang University, Ansan-Si 15588, Republic of Korea.
Yuhyeong JeongDepartment of Mechanical Engineering, Hanyang University, Ansan-Si 15588, Republic of Korea.
Youngjin JeonDepartment of Mechanical Engineering, Hanyang University, Ansan-Si 15588, Republic of Korea.ORCID 0009-0002-2364-1655
Hyungsu JuDepartment of Mechanical Engineering, Hanyang University, Ansan-Si 15588, Republic of Korea.
Jooyong KimDepartment of DH Network Administration, Pangyoro, Bundang-Gu, Seongnam-Si 13487, Republic of Korea.ORCID 0009-0004-0939-2562
Yeonsoo KimDepartment of DH Network Administration, Pangyoro, Bundang-Gu, Seongnam-Si 13487, Republic of Korea.
Junghae HwangDepartment of DH Network Administration, Pangyoro, Bundang-Gu, Seongnam-Si 13487, Republic of Korea.
Dongil ChoiDepartment of DH Network Administration, Pangyoro, Bundang-Gu, Seongnam-Si 13487, Republic of Korea.
Jonghun YoonDepartment of Mechanical Engineering, Hanyang University, Ansan-Si 15588, Republic of Korea.ORCID 0000-0001-7547-3185

Funding

Korea District Heating Corporation 1003542023S090Korea Institute of Industrial Technology KITECH JC-25-0029Ministry of Trade, Industry and Energy P00223311National Research Foundation of Korea 2025-00555072
6 · The paper itself

Abstract

This study establishes experimentally grounded circumferential thermal criteria for heat-shrinkable crosslinked polyethylene (PEX) joint casings by coupling DSC-defined thermal activation with through-thickness thermal lag measured under trench-constrained irradiation. The activation temperature was identified as 140 °C from DSC, while an upper bound of the allowable outer-surface temperature was set to avoid thermal damage during installation. Full-scale temperature mapping revealed persistent circumferential non-uniformity caused by geometric line-of-sight limitations and inter-module gap regions, where the outer-surface temperature remained approximately 10-15 °C lower than directly irradiated locations, and the inner surface exhibited a delayed response due to the low thermal conductivity of PEX. Based on these observations, a two-stage heating sequence-an initial high-power stage followed by a reduced-power soaking stage-was experimentally derived to satisfy dual constraints: achieving inner-surface activation (≥140 °C) while maintaining the outer surface below the conservative outer-surface upper bound (~280 °C) and reducing circumferential temperature differences without surface overheating. Comparative joint tests confirmed that the proposed thermal criteria and sequence promote stable interfacial bonding and cohesive failure in the mastic layer, yielding higher repeatability and smaller strength scatter than conventional manual torch heating. The proposed framework provides experimentally grounded thermal criteria and a transferable procedure for designing heating conditions for heat-shrinkable polymer casing systems under constrained field environments.

Indexed as

crosslinked polyethylene (PEX)DSC-defined thermal activationheat-shrinkable polymerinterfacial bondingthermal criteriatwo-stage heating sequence

Identifiers

PMID41977544
PMCPMC13074769

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.