Evidence map›Paper›PMID 41975385›Full record

ArticleBMC musculoskeletal disorders2026

Intra-operative fluoroscopic measurement accuracy for femoral tunnel aperture positions in anterior cruciate ligament reconstruction.

Jae Ang Sim, Young Jun Kim, Seong Hyup Ham, Jung Min Shin, Byung Hoon Lee

Abstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jae Ang SimDepartment of Orthopaedic Surgery, Gil Medical Center, Gachon University Gil Medical Center, Incheon, 21565, Republic of Korea.
Young Jun KimKorea Institute of Science and Technology (KIST), Seoul, Republic of Korea.
Seong Hyup HamDepartment of Orthopaedic Surgery, Gil Medical Center, Gachon University Gil Medical Center, Incheon, 21565, Republic of Korea.
Jung Min Shin *Department of Rheumatology, Nowon Eulji Medical Center, Eulji University, Seoul, Republic of Korea. jmshin0412@gmail.com.
Byung Hoon Lee *Department of Orthopaedic Surgery, Gil Medical Center, Gachon University Gil Medical Center, Incheon, 21565, Republic of Korea. oselite@naver.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to test an automated analysis software for the three-dimensional (3D) quadrant method and assess the accuracy of femoral tunnel positioning during double-bundle anterior cruciate ligament reconstruction (DB-ACLR) with fluoroscopic assistance versus conventional 3D computed tomography (3D-CT).

methodsWe retrospectively evaluated 32 patients who underwent DB-ACLR between 2010 and 2014. The femoral tunnel location was calculated using three methods: the quadrant fluoroscopy method, the (modified) quadrant method using conventional 3D-CT, and the automated 3D reconstruction method. Two independent observers assessed each knee position. The accuracy of tunnel location on the fluoroscopic radiograph and conventional 3D-CT was compared to the automated 3D reconstruction method.

resultsFemoral tunnel locations measured by the quadrant method using an automated 3D reconstruction method were 19.1 ± 4.8 % of depth and 22.3 ± 7.7 % of height in anteromedial (AM) femoral tunnels, 32.2 ± 6.0% of depth and 48.4 ± 7.7% of height in posterolateral (PL) tunnels. Using fluoroscopy, 20.3 ± 5.0 % of depth and 26.8 ± 8.9 % of height in AM tunnels, and 32.9 ± 5.4% of depth and 50.6 ± 7.9% of height in PL tunnels was achieved. Using conventional 3D CT, 21.3 ± 4.6 % of depth and 26.0 ± 9.1 % of height in AM tunnels, and 34.9 ± 7.1% of depth and 50.1 ± 8.0% of height in PL tunnels was achieved. When analyzed using the Bland-Altman plot, the Limit of Agreement (LOA) in the fluoroscopy group was closer to the equator than conventional 3D CT group in all cases, except for the height of the AM tunnel, which had a slightly lower LOA.

conclusionThe fluoroscopically identified tunnel aperture location was more accurate and reproducible than the one obtained via the quadrant method using conventional 3D-CT imaging. LEVEL OF EVIDENCE: IV CLINICAL RELEVANCE: This study showed the femoral tunnel position on the fluoroscopic image is close to real position in 3D femoral image, Therefore, intraoperative fluoroscopy is can be applied as a feasible method for improving the accuracy of anatomical tunnel positioning.

Indexed as

Anterior Cruciate Ligament ReconstructionFemurAdultAnterior Cruciate LigamentFemaleFluoroscopyHumansImaging, Three-DimensionalMaleReproducibility of ResultsRetrospective StudiesTomography, X-Ray ComputedYoung AdultAnterior cruciate ligament reconstructionComputed tomographyFemoral tunnel positionFluoroscopyImage analysisQuadrant method

Identifiers

PMID41975385
PMCPMC13195977

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.