Evidence map›Paper›PMID 41972313›Full record

ArticleTechnology in cancer research & treatment

Dosimetric Performance Analysis of Pediatric Based Halcyon™ Volumetric Arc Therapy-Based Lung-Sparing Total Body Irradiation.

Allison Haertter, Keshav Goel, Jacob Niculcea, Taoran Li, Christine E Hill-Kayser, John Plastaras, Michael J LaRiviere, Michele M Kim

Abstract read
In one paragraph

Article in Technology in cancer research & treatment. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Allison HaertterNew York Proton Center, New York, NY.
Keshav GoelPerelman School of Medicine, University of Pennsylvania, Philadelphia, PA.ORCID 0009-0008-3070-9463
Jacob NiculceaPerelman School of Medicine, University of Pennsylvania, Philadelphia, PA.
Taoran LiDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA.
Christine E Hill-KayserDepartment of Radiation Oncology, Children's Hospital of Philadelphia, University of Pennsylvania, Philadelphia, PA.
John PlastarasDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA.
Michael J LaRiviereDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA.
Michele M KimDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

IntroductionHalcyon™ O-ring linear accelerators (linacs) provide a robust and efficient radiotherapy option for clinics. Interest in volumetric arc therapy (VMAT) based total body irradiation (TBI) has grown, with most current VMAT TBI protocols employing C-arm linacs; however, the feasibility of Halcyon-based VMAT TBI has been recently hypothesized. This study investigates the planning feasibility and dosimetric quality of VMAT-based, lung-sparing TBI delivered by Halcyon linac to pediatric patients.Methods10 pediatric patients (94 - 134 cm in height) previously treated to 12 Gy TBI through traditional 3D planning techniques were retrospectively replanned on a Halcyon linac. 2-3 VMAT plans containing 4-6 isocenters each with 2-2.5 arcs were created to treat the head, abdomen, and legs, with 1-2 static-gantry treatment matching areas being used between VMAT planning regions.ResultsLung doses were significantly reduced below the clinically significant level of 8 Gy, achieving mean doses of 6.66 ± 0.52 Gy (55.5% ± 4.3%). Target coverage was achieved with D90% of 77.5% ± 12.5% and homogeneity indexes of 0.92 ± 0.1. Planning time took 5-6 hours per patient: 1.5 hours for contouring and field placement and 3.5-4.5 hours for plan optimization and dose calculations. Using a dose rate of 800 MU/min field delivery time took an average of 20.8 ± 7 minutes with average portal dosimetry quality assurance passing rates of 99.6% and 99.9% for 2%/2mm and 3%/3mm gamma analysis metrics.ConclusionVMAT lung sparing TBI via Halcyon linacs is feasible and dosimetrically acceptable, with greatest applicability to smaller patients (<100 cm). Planning and setup complexity increases dramatically for larger patients (>100 cm) due to the smaller maximum field sizes (28 x 28 cm2) achievable. Future developments in software-based automations for target delineation, multiple field matching, and plan optimization could allow for more practicable treatment of larger patients.

Indexed as

LungNeoplasmsOrgan Sparing TreatmentsRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedWhole-Body IrradiationAdolescentChildChild, PreschoolFemaleHumansMaleOrgans at RiskParticle AcceleratorsRadiometryRadiotherapy Dosagebody mass indexcancercancer treatmentcomputed tomography, CTdeliverylunglung cancerradiationradiation therapy

Identifiers

PMID41972313
PMCPMC13080152

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.