Evidence map›Paper›PMID 41972064›Full record

ArticleQuantitative imaging in medicine and surgery2026

Influence of slice thickness on computed tomography perfusion-derived ischemic core volume accuracy in acute ischemic stroke.

Chuluunbaatar Otgonbaatar, Huijin Song, Keun-Hwa Jung, Inpyeong Hwang, Tae Jin Yun, Chul-Ho Sohn

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chuluunbaatar OtgonbaatarMedical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-8533-6165
Huijin SongBiomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea.
Keun-Hwa JungDepartment of Neurology, Seoul National University Hospital, Seoul, Republic of Korea.
Inpyeong HwangDepartment of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
Tae Jin YunDepartment of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
Chul-Ho SohnDepartment of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Computed tomography (CT) perfusion enables quantitative assessment of cerebral hemodynamic and physiologic parameters and is widely employed for triaging patients with acute ischemic stroke; however, the absence of standardized acquisition protocols for ischemic core estimation remains a major limitation. This study aimed to determine the optimal CT slice thickness for quantifying ischemic core volume derived from CT perfusion in patients with acute ischemic stroke, using diffusion-weighted imaging (DWI)-derived ischemic core volume as the reference standard. Methods: In this retrospective study, patients with acute ischemic stroke who met the inclusion criteria were reviewed. CT perfusion data were reconstructed with slice thicknesses of 1, 3, 5, 7, and 10 mm to evaluate their impact on ischemic core volume quantification. Ischemic core volumes were calculated using fully automated post-processing software. The ischemic core was defined using thresholds of relative cerebral blood flow (rCBF) <20-38% and relative cerebral blood volume (rCBV) <34-42%. The optimal slice thickness was identified based on the lowest mean absolute error (MAE), the smallest bias and narrowest 95% limits of agreement (LoA) in Bland-Altman analysis, and the highest intraclass correlation coefficient (ICC) compared with DWI-derived ischemic core volume. Results: A total of 87 patients (mean age ± standard deviation, 69.64±12.27 years; 49 males) were included. Among the different slice thicknesses, the lowest MAE was observed at the rCBF <38% threshold compared to rCBF <30%. Bland-Altman analysis and ICC results indicated that 3 mm (bias, 5.04 mL; 95% LoA, -35.29 to 45.38; ICC =0.961), 5 mm (bias, 4.55 mL; 95% LoA, -37.41 to 46.51; ICC =0.961), and 7 mm (bias, 4.75 mL; 95% LoA, -35.14 to 44.66; ICC =0.961) slice thicknesses yielded the most accurate estimates of ischemic core volume when using rCBF <38%. In contrast, 1 mm (bias, 6.71 mL; 95% LoA, -36.86 to 50.29; ICC =0.951) and 10 mm (bias, 9.12 mL; 95% LoA, -47.42 to 65.67; ICC =0.905) reconstructions demonstrated lower agreement with DWI-derived measurements. Conclusions: CT perfusion data reconstructed at slice thicknesses of 3-7 mm provided the most accurate estimation of ischemic core volume, at both commonly used and optimal perfusion thresholds, compared with thinner (1 mm) or thicker (10 mm) slice thicknesses.

Indexed as

acute ischemic strokeComputed tomography perfusion (CT perfusion)ischemic core volumeslice thickness

Identifiers

PMID41972064
PMCPMC13066842

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.