Evidence map›Paper›PMID 41971114›Full record

ArticleJournal of the Korean Society of Radiology2026

[Development of a Computer-Aided Automatic-Detection Deep-Learning Algorithm to Identify a Urinary Stone in Low-Dose Non-Enhanced CT Images].

Nam Hoon Kim, Sung Bin Park, Chang-Won Jeong

Abstract readEnglish Abstract
In one paragraph

Article in Journal of the Korean Society of Radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To develop a computer-aided automatic-detection (CAD) deep-learning algorithm to identify a urinary stone in low-dose non-enhanced CT images. Materials and Methods: This retrospective study was performed at a single institution. Over a period of 14 months, the low-dose CT images of 486 patients with suspicious urinary stone disease were collected. The labeling of urinary stones, or not, in low-dose CT images was performed by an expert uroradiologist as a reference standard. We used labeled CT scans (axial 1,144, coronal 1,279, sagittal 765). We developed a CAD deep-learning algorithm using the YOLO v7 model. The data ratio for training, validation, and testing was set at 6:3:1. The performance of our proposed CAD deep-learning algorithm at identifying a urinary stone was analyzed using several parameters, such as the mean average performance (mAP), precision, recall, F1-score, and accuracy. Results: The mAP of our proposed algorithm was 95%. The accuracy of the CAD deep-learning algorithm for urinary stone detection was 93% and 92%, in the training and test sets, respectively. Conclusion: The proposed CAD algorithm developed using a deep-learning model has high performance at urinary stone detection in low-dose CT images.

Identifiers

PMID41971114
PMCPMC13062379

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.