Evidence map›Paper›PMID 41970752›Full record

ArticleJournal of orthopaedic case reports2026

Recurrent Ceramic Femoral Head Fracture in Dual Mobility Total Hip Arthroplasty: A Case Report.

Mohamad Khaled Ghannam, Elliot Sappey-Marinier, Michel Bonnin, Tarik Ait Si Selmi, Mohammad Alajji, Axel Schmidt

Abstract readCase Reports
In one paragraph

Article in Journal of orthopaedic case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mohamad Khaled GhannamDepartment of Orthopaedic Surgery, Ramsay Sante, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.
Elliot Sappey-MarinierDepartment of Orthopaedic Surgery, Ramsay Sante, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.
Michel BonninDepartment of Orthopaedic Surgery, Ramsay Sante, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.
Tarik Ait Si SelmiDepartment of Orthopaedic Surgery, Ramsay Sante, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.
Mohammad AlajjiDepartment of Orthopaedic Surgery, Ramsay Sante, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.
Axel SchmidtDepartment of Orthopaedic Surgery, Ramsay Sante, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Ceramic femoral heads reduce wear in total hip arthroplasty (THA), yet fracture remains a rare but serious complication. Reports almost exclusively concern ceramic-on-ceramic bearings; cases in dual mobility constructs are exceptional. We describe, to our knowledge, the first report of two successive ceramic femoral head fractures occurring in the same dual mobility hip in a single patient, and we outline plausible mechanical contributors. Case Report: Sixty-six-year-old White European man with no major comorbidities underwent primary THA with a dual mobility construct at another institution. Ten days later, he developed mechanical pain and audible noises without trauma; imaging demonstrated a ceramic femoral head fracture. Urgent revision replaced the acetabular component and femoral stem, and a new ceramic head was implanted; recovery was initially satisfactory. Twenty-two months later, during a torsional movement without high-energy trauma, he experienced sudden pain and functional impairment of the same hip. Imaging again confirmed a ceramic femoral head fracture. At re-revision, fragmented ceramic debris was found; the acetabular shell and the trunnion were intact and well fixed. The ceramic head was exchanged for a cobalt-chromium head with a compatible polyethylene insert, with extensive irrigation. Eight months later, he was pain-free with a full range of motion and returned to normal activities. The patient's ethnic background was not recorded. Conclusion: This case shows that dual mobility constructs are not immune to ceramic femoral head fracture and that recurrence is possible even with correct component positioning. The combination of increased femoral offset and an extended ceramic head, particularly in a patient with elevated body mass index, may raise stresses at the head-trunnion junction and precipitate failure. Clinicians should weigh patient and implant-related mechanical demands when selecting ceramic heads for dual mobility constructs and consider alternatives when risk appears high.

Indexed as

Ceramic femoral head fracturedual mobility hip arthroplastyfemoral offsethead–trunnion junction

Identifiers

PMID41970752
PMCPMC13062243

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked