Evidence map›Paper›PMID 41968285›Full record

ArticleMagnetic resonance in medicine2026

Electromagnetic and Electrophysiological Modeling of Cardiac Stimulation Thresholds in 13 MRI Gradient Systems and 56 Body Models.

Valerie Klein, Mathias Davids, Natalie G Ferris, Jonathan Edmonson, Matthias Gebhardt, Dominik Rattenbacher, Johan S van den Brink, Michael Steckner, Lawrence L Wald, Bastien Guérin

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Valerie KleinA. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID https://orcid.org/0000-0002-7600-6172
Mathias DavidsA. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Natalie G FerrisA. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Jonathan EdmonsonMedtronic Cardiac Rhythm Management, Minneapolis, Minnesota, USA.
Matthias GebhardtSiemens Healthineers, Erlangen, Germany.
Dominik RattenbacherSiemens Healthineers, Erlangen, Germany.
Johan S van den BrinkPhilips Healthcare, Best, the Netherlands.
Michael StecknerMKS Consulting, Beachwood, Ohio, USA.ORCID https://orcid.org/0000-0001-6854-9348
Lawrence L WaldA. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Bastien GuérinA. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA.

Funding

Mitigation of peripheral nerve stimulation (PNS) in MRIR01EB028250 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Bastien Guerin · 2020 to 2026
$3.6M
Modeling, measurement and prediction of cardiac magneto-stimulation thresholdsR01EB033853 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Bastien Guerin, Christopher T Nguyen · 2023 to 2026
$2.4M
NIBIB NIH HHS R01 EB028250NIBIB NIH HHS R01 EB033853NIH HHS R01EB028250NIH HHS R01EB033853
6 · The paper itself

Abstract

purposeThe MRI safety standard IEC 60601-2-33 limits the maximum dB/dt and E-field induced by MRI gradients to protect patients from cardiac stimulation (CS). Those limits were set in the early 2000s based on a compilation of electrode stimulation measurements in animals as well as electromagnetic calculations in a homogeneous ellipsoid. We re-evaluate CS in MRI using state-of-the-art electromagnetic and electrophysiological modeling in realistic body models and gradient coils.

methodsWe predicted CS thresholds in 56 realistic body models and 13 commercial gradient systems for trapezoidal waveforms with rise times (the time during which the gradient amplitude is ramped from zero to maximum) ranging from 0.1 to 5.0 ms. We used threshold predictions in individual body models to estimate the gradient field amplitude below which the probability of occurrence of a CS adverse event is < 2 ppb, the historically agreed upon probability used in IEC 60601-2-33.

resultsWe found that the variability of CS thresholds due to differences in anatomy and body habitus was 10%-36%, depending on rise time, while the CS threshold variability across gradient coils was 27%. In the range of typically used MRI rise times (≤ 2.5 ms), the predicted gradient amplitude associated with a CS probability of 2 ppb is > 5.5X higher than the IEC CS limit.

conclusionDetailed simulations in a large population of realistic body models and gradient coils indicate that the IEC CS limit is substantially lower (more conservative) than the predicted gradient amplitude associated with a 2-ppb probability for CS.

Indexed as

Electric StimulationHeartMagnetic Resonance ImagingModels, CardiovascularComputer SimulationElectromagnetic FieldsHumans

Identifiers

PMID41968285
PMCPMC13301364

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.