Evidence map›Paper›PMID 41967860›Full record

ArticleInterdisciplinary cardiovascular and thoracic surgery2026

Haemodynamic Early Outcomes of Sinus Plication for Bicuspid Aortic Valve Repair.

Kay Maeda, Nao Ichihara, Toshio Baba, Tomonobu Abe, Atsushi Yamaguchi, Dai Une, Mikizou Nakai, Hiroshi Matsuura, Takeshiro Fujii, Takashi Kunihara

Abstract read
In one paragraph

Article in Interdisciplinary cardiovascular and thoracic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kay MaedaDepartment of Cardiac Surgery, The Jikei University School of Medicine, Tokyo, 105-8461, Japan.ORCID 0000-0003-2199-0296
Nao IchiharaDepartment of Cardiac Surgery, The Jikei University School of Medicine, Tokyo, 105-8461, Japan.
Toshio BabaDepartment of Cardiovascular Surgery, Bellland General Hospital, Sakai, 599-8247, Japan.
Tomonobu AbeDivision of Cardiovascular Surgery, Department of General Surgical Science, Gunma University, Maebashi, 371-8511, Japan.ORCID 0000-0002-9149-5736
Atsushi YamaguchiDepartment of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, Saitama, 330-8503, Japan.
Dai UneDepartment of Cardiovascular Surgery, Kawasaki Medical School, Okayama, 701-0192, Japan.
Mikizou NakaiDepartment of Cardiovascular Surgery, National Hospital Organization Okayama Medical Center, Okayama, 701-1192, Japan.
Hiroshi MatsuuraDepartment of Cardiovascular Surgery, NTT Higashi Nihon Sapporo Hospital, Sapporo, 060-0061, Japan.
Takeshiro FujiiDivision of Cardiovascular Surgery, Department of Surgery, Toho University Faculty of Medicine, Tokyo, 143-8541, Japan.
Takashi KuniharaDepartment of Cardiac Surgery, The Jikei University School of Medicine, Tokyo, 105-8461, Japan.ORCID 0000-0001-6903-6501

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesPostoperative stenosis negatively affects durability after bicuspid aortic valve (BAV) valvuloplasty. This study was performed to evaluate the haemodynamic efficacy of sinus plication (SP) to avoid stenosis after asymmetrical BAV repair.

methodsBetween 2018 and 2023, 41 patients with BAV (33.3 ± 11.5 years, 40 males) with moderate-severe aortic regurgitation (AR) underwent aortic valve repair with (SP group, n = 14) or without (NSP group, n = 27) SP. SP was performed to reduce the circumference of the fused sinus and restore sinus contour symmetry. Preoperative and postoperative haemodynamic parameters were assessed at discharge and 1 year using transthoracic echocardiography.

resultsNo deaths occurred within 1 year after surgery in either group. AR was well controlled and adequate left ventricular reverse remodelling was observed in both the groups up to 1 year postoperatively. At 1 year, lower transvalvular peak pressure gradient (PG) and maximum transvalvular flow velocity (Vmax) were observed in the SP group (peak PG: 17.7 ± 5.5 mmHg; % change -8.8% ± 1.1%, Vmax: 1.9 ± 0.31 m/s; % change -13.1% ± 2.1%) compared with the NSP group (peak PG: 24.7 ± 9.6 mmHg; +8.8% ± 1.3%, Vmax: 2.58 ± 0.62 m/s; +9.3% ± 2.5%), while there were no clear differences in % changes of peak PG or Vmax between the groups after adjustment for covariates.

conclusionsIn BAV repair, SP was potentially associated with lower peak PG and Vmax at 1 year. These findings suggest that SP may enhance haemodynamic stability in BAV repair.

Indexed as

Aortic ValveAortic Valve InsufficiencyBicuspid Aortic Valve DiseaseHemodynamicsAdultFemaleHumansMaleMiddle AgedRetrospective StudiesTime FactorsTreatment OutcomeYoung Adultaortic valve repairbicuspid aortic valvesinus plication

Identifiers

PMID41967860
PMCPMC13125754

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.