Evidence map›Paper›PMID 41965868›Full record

ArticleScientific reports2026

Impact of generator replacement and other device procedures on timing of implantable cardioverter-defibrillator lead removal.

Andrzej Kutarski, Wojciech Jacheć, Paweł Stefańczyk, Łukasz Tułecki, Dorota Nowosielecka

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Andrzej KutarskiDepartment of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland.
Wojciech JachećDepartment of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland.
Paweł StefańczykDepartment of Cardiology, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland.
Łukasz TułeckiDepartment of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, 22-400, Zamość, Poland.
Dorota NowosieleckaDepartment of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, 22-400, Zamość, Poland. dornowos@wp.pl.

Funding

Medical University of Silesia BNW-1-018/N/5/K
6 · The paper itself

Abstract

There is a suggestion that implantable cardioverter-defibrillator (ICD) lead failure is related to generator replacement. The aim of the study was to investigate the impact of ICD lead implantation and subsequent procedures on the risk of infection and lead performance. Data from 1068 transvenous lead extraction (TLE) procedures with ICD lead removal were analyzed. It was shown that the most common cause of ICD lead removal was infection (36%), mechanical lead damage and dysfunction of undamaged leads (34% and 21%). The most common procedures preceding TLE were primary implantation (56%) and generator replacement (27%). Older age of the lead increased the probability of lead extraction due to mechanical damage [HR = 1.107; 95%CI (1.083–1.113), p < 0.001], other procedures were more likely to result in increased risk of infection [HR = 2.517; 95%CI (1.815–3.492), p < 0.001]. In lead age-matched groups the probability of lead extraction due to mechanical damage increased after reimplantation [HR = 1.614;95%CI (1.306–1.994), p < 0.001] and because of the infection it was even higher after reimplantation [HR = 1.500;95%CI (1.184–1.899), p < 0.001] and upgrading/revision procedures [HR = 2.372;95%CI (1.783–3.154), p < 0.001]. There is a link between the age of an ICD lead and the probability of its mechanical damage. Generator replacement is associated both with early mechanical lead damage and infections, with their risk additionally increased by such procedures as system upgrading/revision.

Indexed as

Defibrillators, ImplantableDevice Lead ExtractionDevice RemovalAgedEquipment FailureFemaleHumansTime FactorsICD generator changeICD generator replacementICD lead failureICD lead survival

Identifiers

PMID41965868
PMCPMC13230724

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.