Evidence map›Paper›PMID 41965676›Full record

ArticleBMC research notes2026

Design of a fixture for precise perpendicular cuts in bone-implant sample preparation.

Mihail Genchev, Bianca Riedel, Coralie Nagels, Hagen Schmal, Eva Johanna Kubosch, Maria Carolina Lanzino, Michael Seidenstuecker

Abstract read
In one paragraph

Article in BMC research notes, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mihail GenchevG.E.R.N. Center of Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Albert-Ludwigs-University of Freiburg Medical Center, Hugstetter Straße 55, 79106, Freiburg, Germany.
Bianca RiedelG.E.R.N. Center of Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Albert-Ludwigs-University of Freiburg Medical Center, Hugstetter Straße 55, 79106, Freiburg, Germany.
Coralie NagelsG.E.R.N. Center of Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Albert-Ludwigs-University of Freiburg Medical Center, Hugstetter Straße 55, 79106, Freiburg, Germany.
Hagen SchmalDepartment of Orthopedics and Trauma Surgery, Faculty of Medicine, Medical Center-Albert-Ludwigs-University of Freiburg, Albert-Ludwigs-University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
Eva Johanna KuboschDepartment of Orthopedics and Trauma Surgery, Faculty of Medicine, Medical Center-Albert-Ludwigs-University of Freiburg, Albert-Ludwigs-University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
Maria Carolina LanzinoInstitute for Ceramic Materials and Technologies (IKMT), University of Stuttgart, Stuttgart, Germany.
Michael SeidenstueckerG.E.R.N. Center of Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Albert-Ludwigs-University of Freiburg Medical Center, Hugstetter Straße 55, 79106, Freiburg, Germany. michael.seidenstuecker@uniklinik-freiburg.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate specimen preparation is essential for biomechanical push-out testing of bone–implant interfaces. A common source of error arises when implants such as pins or screws are not cut exactly perpendicular to their axis. This results in oval or irregular cross-sections that compromise the validity of mechanical testing. In this study, we present a newly developed holder designed to ensure perpendicular sectioning of bone-anchored implants. Titanium pins coated with tricalcium phosphate (TCP) and GB14 were implanted in rabbit condyles and prepared for thin-section analysis using the Donath method. The roundness of implant cross-sections was quantitatively assessed with ImageJ (FIJI 1.53t) based on circularity and aspect ratio parameters. Compared with conventional freehand sectioning techniques, which exhibited a roundness of 0.83 ± 0.06 and an aspect ratio of 1.22 ± 0.09, the novel holder achieved markedly improved geometrical accuracy, with a roundness of 0.99 ± 0.002 and an aspect ratio of 1.003 ± 0.002. This difference was statistically significant (p < 0.01). These results demonstrate that the device effectively minimizes geometric artifacts during sample preparation, thereby enhancing reproducibility and reliability in subsequent biomechanical testing. Although the validation was limited to rabbit condyles, the holder is a simple and versatile instrument with the potential for application across different implant types and experimental models.

Indexed as

Bone-Implant InterfaceSpecimen HandlingAnimalsBiomechanical PhenomenaBone NailsCalcium PhosphatesRabbitsReproducibility of ResultsTitaniumCalcium PhosphatesTitaniumtricalcium phosphateBone-implant interfacePerpendicular cutting holderPush-out testRoundness analysisSpecimen preparation

Identifiers

PMID41965676
PMCPMC13122900

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.