Evidence map›Paper›PMID 41964517›Full record

ArticleJournal of cardiovascular electrophysiology2026

Incidence and Predictors of Successful Lead Extraction With Short Active Mechanical Extraction Sheaths Only.

Caroline Wiederkehr, Noah Kuster, Michelle Bebié, Jan Steffel, Andreas Haeberlin, Alexander Breitenstein, Daniel Hofer

Abstract read
In one paragraph

Article in Journal of cardiovascular electrophysiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Caroline WiederkehrDepartment of Cardiology, Triemli Hospital Zurich, Zurich, Switzerland.ORCID 0009-0006-1566-6413
Noah KusterDepartment of Cardiology, University Hospital of Zurich, Division of Electrophysiology, Zurich, Switzerland.
Michelle BebiéDepartment of Cardiology, University Hospital of Zurich, Division of Electrophysiology, Zurich, Switzerland.
Jan SteffelDepartment of Cardiology, University Hospital of Zurich, Division of Electrophysiology, Zurich, Switzerland.
Andreas HaeberlinDepartment of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Alexander BreitensteinDepartment of Cardiology, University Hospital of Zurich, Division of Electrophysiology, Zurich, Switzerland.
Daniel HoferDepartment of Cardiology, Triemli Hospital Zurich, Zurich, Switzerland.ORCID 0000-0001-8164-6329

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimsTransvenous lead extraction (TLE) is increasingly performed for malfunction or infection of cardiac implantable electronic devices (CIED). Active mechanical rotational sheaths facilitate extraction and are available in short and long sizes, but it is unclear how many patients short active mechanical extraction sheaths (SAMES) are sufficient for TLE, and in which patients they may facilitate TLE. This study aimed to evaluate the incidence and predictors of successful lead extraction using only SAMES.

methodsWe retrospectively analyzed patients who underwent TLE at the University Hospital Zurich from 2013 until 2023 regarding the use of short or long active mechanical extraction sheaths, as well as clinical and radiological success and complications.

resultsA total of 568 TLEs were performed from January 2013 until December 2023. In 55 cases (9.7%), TLE was successful using only SAMES. Independent predictors for successful lead extraction using only SAMES in multivariate analysis were shorter lead dwell time (OR: 0.98, 95% CI: 0.97-0.99, p < 0.001) and use of anticoagulation (OR: 0.44, 95% CI: 0.19-1.00, p = 0.05). Complications occurred at a lower rate when only SAMES were used (All complications 12.7% vs. 24.2%, minor complications 9.1% vs. 18.7%, perioperative death 0% vs. 1.7%).

conclusionIn 10% of patients undergoing TLE, SAMES are sufficient for successful lead extraction. SAMES may be a sensible choice as the primary extraction tool in patients with chronic anticoagulation and shorter lead dwell time, as these factors predict a higher likelihood of success in TLE with SAMES only.

Indexed as

Cardiac CathetersDefibrillators, ImplantableDevice Lead ExtractionDevice RemovalPacemaker, ArtificialProsthesis-Related InfectionsAgedAged, 80 and overEquipment DesignFemaleHumansIncidenceMaleMiddle AgedRetrospective StudiesRisk Factorsactive mechanical sheathscomplicationslead extractionoutcome

Identifiers

PMID41964517
PMCPMC13269861

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.