Evidence map›Paper›PMID 41964168›Full record

ArticleInternational journal of laboratory hematology2026

Analytical and Clinical Performance of the Atellica HEMA 580 Haematology Analyzer: A Comparison With the ADVIA 2120i.

Hyeongyu Lee, Jooyoung Cho, Gilsung Yoo, Juwon Kim

Abstract readComparative Study
In one paragraph

Article in International journal of laboratory hematology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hyeongyu LeeDepartment of Laboratory Medicine, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea.
Jooyoung ChoDepartment of Laboratory Medicine, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea.ORCID https://orcid.org/0000-0002-9628-2334
Gilsung YooDepartment of Laboratory Medicine, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea.
Juwon KimDepartment of Laboratory Medicine, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe Atellica HEMA 580 is a novel haematology analyser providing eight-part leukocyte differential and optical platelet (PLT) counting. We compared its analytical and clinical performance with that of the ADVIA 2120i.

methodsA total of 796 residual whole blood specimens were analysed. Carryover, linearity and precision were assessed. Inter-instrument comparison was performed for complete blood counts and five-part differential (5-Diff) parameters using Passing-Bablok regression and Bland-Altman analyses. Additional regression against manual microscopy was conducted for flagged samples, including PLT, reticulocytes and common 5-Diff parameters.

resultsCarryover was < 1% for all parameters. Linearity was excellent (R

conclusionThe Atellica HEMA 580 demonstrated reliable analytical performance and strong agreement with the ADVIA 2120i. This supports its suitability as a routine haematology analyser, providing accurate and clinically comparable results.

Indexed as

Hematologic TestsBlood Cell CountHumansPlatelet CountReproducibility of ResultsADVIA 2120iAtellica HEMA 580complete blood countHaematology analyserperformance evaluation

Identifiers

PMID41964168
PMCPMC13357788

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.