Evidence map›Paper›PMID 41963806›Full record

ArticleBMC cardiovascular disorders2026

Lesion formation and impedance dependence of v-HPSD ablation (QDOT-MICRO™) versus conventional power-control (SmartTouch™ SF): a head-to-head comparison in an ex vivo porcine model.

Jinhong Guo, Yingjie Wang, Meixue Jia, Shuai Chen, Bin Ning

Abstract readComparative Study
In one paragraph

Article in BMC cardiovascular disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jinhong GuoDepartment of Cardiology, the Affiliated Fuyang People's Hospital of Anhui Medical University, Fuyang, Anhui province, 236000, China.
Yingjie WangDepartment of Cardiology, the Affiliated Fuyang People's Hospital of Anhui Medical University, Fuyang, Anhui province, 236000, China.
Meixue JiaDepartment of Cardiology, the Affiliated Fuyang People's Hospital of Anhui Medical University, Fuyang, Anhui province, 236000, China.
Shuai ChenDepartment of Cardiology, the Affiliated Fuyang People's Hospital of Anhui Medical University, Fuyang, Anhui province, 236000, China.
Bin NingDepartment of Cardiology, the Affiliated Fuyang People's Hospital of Anhui Medical University, Fuyang, Anhui province, 236000, China. fysyynb0301@163.com.

Funding

Anhui Provincial Health and Scientific Research Project Grant No. AHWJ2023A20336
6 · The paper itself

Abstract

objectiveThis study aims to compare the lesion characteristics of v-HPSD and conventional PC ablation modes and to quantitatively evaluate their dependence on impedance variation.

methodsThe study was performed using an ex vivo porcine heart model. Ablations in the v-HPSD group were carried out with a QDOT-MICRO™ catheter, whereas conventional power-control (PC) ablations employed a Thermocool-STSF® catheter, set at a fixed power of 40 W and terminated upon reaching an ablation index of 500. To study the effect of baseline impedance, it was dynamically adjusted to low, medium, and high preset levels by incorporating a sliding rheostat in series with the ablation circuit.

resultsAblation lesions in the PC group were characterized by significantly smaller superficial and maximum diameters but greater depth compared to the v-HPSD group (Superficial diameter: 5.19±0.71 mm vs. 5.83±0.73 mm, p<0.01; Maximum diameter: 7.04±0.95 mm vs. 7.79±0.96 mm, p<0.01; Depth: 4.67±0.22 mm vs. 3.50±0.40 mm, p<0.01). Although the mean lesion volume was larger in the PC group, this difference did not reach statistical significance (74.08±30.02 mm³ vs. 65.98±21.99 mm³, p=0.097). The ablation mode and impedance level demonstrated a significant interaction, which differentially affected the lesion parameters: highly significant for maximum depth and mean volume (P < 0.001), significant for superficial diameter (P < 0.05), and non-significant for maximum diameter (P = 0.587).

conclusionThe v-HPSD mode exhibits superior adaptability, achieving comparable overall lesion volume in high-impedance settings by generating wider and depth-stable lesions, which underscores its enhanced performance predictability.

Indexed as

Cardiac CathetersCatheter AblationAnimalsElectric ImpedanceEquipment DesignModels, AnimalSus scrofaSwineBaseline impedanceLesion sizePower control(PC)Radiofrequency ablationVery high Power short duration(v-HPSD)

Identifiers

PMID41963806
PMCPMC13214096

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.