Evidence map›Paper›PMID 41960195›Full record

ArticleHealthcare technology letters

In-Vivo Hand Mass Determination and an Anthropometric Investigation on Segment Length and Radius for Prosthetic Segment Design.

Panagiotis Tsakonas, Neil D Evans, Joseph Hardwicke, Shervanthi Homer-Vanniasinkam, Michael J Chappell

Erratum issuedAbstract read
In one paragraph

Article in Healthcare technology letters. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Panagiotis TsakonasSchool of Engineering University of Warwick Coventry UK.ORCID https://orcid.org/0000-0002-6265-7425
Neil D EvansSchool of Engineering University of Warwick Coventry UK.
Joseph HardwickeInstitute of Applied & Translational Technologies in Surgery Coventry UK.
Shervanthi Homer-VanniasinkamUniversity College London, School of Engineering London UK.
Michael J ChappellSchool of Engineering University of Warwick Coventry UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper aims to demonstrate the validity of the use of a cylindrical approximation for human fingers and a parallelepiped approximation of the palm, from a modelling perspective, for the determination of the mass of the hand. The goal is to provide an intuitive way of determining the length and radius of missing segments from partial hand amputees based on palm dimensions and determine the corresponding mass based on the previous two approximations. In-vivo hand mass measurements were taken from 23 able-bodied participants using Archimedes' water displacement method to verify the geometric approximations used. Furthermore, an anthropometric investigation on how segment length and radius change with respect to palm dimensions was undertaken and the estimates found, which can then be used in supporting the design of prosthetic segments in a personalised context.

Indexed as

anthropometric measurementscylindrical approximationfinger amputationhand massupper limb

Identifiers

PMID41960195
PMCPMC13058727

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.