Evidence map›Paper›PMID 41955571›Full record

ArticleMagnetic resonance in medicine2026

Water/Fat Separated Echo Planar Time-Resolved Imaging (WFS-EPTI) for Distortion-Free Multi-Contrast MRI.

Zhangxuan Hu, Timothy G Reese, Lawrence L Wald, Jonathan R Polimeni, Zijing Dong, Fuyixue Wang

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zhangxuan HuAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Timothy G ReeseAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Lawrence L WaldAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Jonathan R PolimeniAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Zijing DongAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID https://orcid.org/0000-0001-9334-0968
Fuyixue WangAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID https://orcid.org/0000-0001-8975-2775

Funding

Advancing fMRI Acquisition through Dissemination of EPTI- An Efficient Distortion-Free Multi-Contrast Imaging TechnologyU24NS129893 · NINDS · MASSACHUSETTS GENERAL HOSPITAL · PI Fuyixue Wang · 2023 to 2026
$2.6M
Developing next-generation imaging technologies for in-vivo mesoscale diffusion MRI and microstructure imagingR01EB036507 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Fuyixue Wang · 2025 to 2026
$1.3M
Imaging brain-wide subarachnoid and perivascular cerebrospinal fluid flow in aging and Alzheimer's diseaseR00AG083056 · NIA · MASSACHUSETTS GENERAL HOSPITAL · PI Zijing Dong · 2025 to 2026
$493k
NIA NIH HHS R00 AG083056NIBIB NIH HHS R01 EB036507NIH HHS P41-EB030006NIH HHS R00-AG083056NIH HHS R01-EB019437NIH HHS R01-EB036507NIH HHS U24-NS129893NINDS NIH HHS U24 NS129893
6 · The paper itself

Abstract

purposeEcho-planar time-resolved imaging (EPTI) provides distortion- and T2/T2* blurring-free multi-echo/multi-contrast imaging with fast speed, making it an efficient acquisition method for various MRI applications. Here, we aim to achieve water-fat separation for EPTI to improve fat signal removal for brain/body imaging applications. THEORY AND

methodsA water/fat separated EPTI (WFS-EPTI) technique is developed, which leverages the intrinsic multi-echo data provided by EPTI readout and introduces a novel strategy for highly-accelerated spatiotemporal encoding and reconstruction to separate water and fat signals. Specifically, DIXON encoding is integrated into the spatiotemporal acquisition by acquiring the echo train at scheduled TEs and echo-spacing, therefore modulating the rapidly changing fat phase evolution across EPTI readout into a more uniform, coherent manner (e.g., in-phase and out-of-phase conditions for odd and even image series). This enables robust subspace representations even in the presence of fat signals. A joint subspace reconstruction is then proposed, which separately performs data consistency for each echo group to ensure fidelity, while jointly leveraging shared information to improve conditioning. Furthermore, an auto-calibrated WFS-EPTI is developed to improve motion robustness for abdominal imaging, and a data-driven basis extraction is employed to address imperfect in-phase/out-of-phase conditions.

resultsBoth phantom experiments and in vivo human imaging across multiple body regions-including brain, head-neck, and abdomen-demonstrated the feasibility of the proposed method.

conclusionThe proposed WFS-EPTI can provide water/fat separation in rapid acquisition and obtain high resolution, distortion-free multi-contrast/quantitative imaging in the presence of fat signals.

Indexed as

Adipose TissueEcho-Planar ImagingImage Processing, Computer-AssistedMagnetic Resonance ImagingAlgorithmsBrainHumansPhantoms, ImagingWaterWaterbody imagingchemical shift artifactsecho‐planar imaging (EPI)fat saturationfat suppressionsubspace reconstruction

Identifiers

PMID41955571
PMCPMC13269247

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.