Evidence map›Paper›PMID 41955001›Full record

ArticleJMIR human factors2026

Health Information Technology-Related Loss of Central Surveillance Data in a Heart Intensive Care Unit: Multi-Framework Case Report.

Md Shafiqur Rahman Jabin

Abstract read
In one paragraph

Article in JMIR human factors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Md Shafiqur Rahman JabinDepartment of Medicine and Optomtery, Linnaeus University, Universitetsplatsen 1, Kalmar, Sweden, 44 07915673612.ORCID 0000-0003-0197-8716

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Centralized electronic surveillance systems are widely used in intensive care settings to support continuous physiological monitoring and patient safety. Failures in health information technology (HIT) infrastructure can disrupt workflows, reduce situational awareness, and create latent risks for serious harm. Understanding such events requires analytic approaches that go beyond single-classification frameworks. Objective: This study aimed to classify and analyze an HIT-related incident that involved loss of central surveillance data in a heart intensive care unit using multiple complementary patient safety and human factors frameworks. Methods: This study is a qualitative case report analysis of an incident in which a central surveillance system intermittently lost server connectivity, resulting in unavailability and loss of monitoring data. The narrative was derived from an incident report and supporting documentation and was translated and linguistically adapted for publication. The incident was independently classified using 5 frameworks: the International Classification for Patient Safety (ICPS), the Health Information Technology Classification System (HIT-CS), Systems Engineering Initiative for Patient Safety (SEIPS) 2.0, the sociotechnical model by Sittig and Singh, and the Human Factors Analysis and Classification System for health care (HFACS-Healthcare). Findings were synthesized across frameworks. Results: All 5 frameworks characterized the event as an HIT-driven system failure involving information unavailability, delayed detection, and multi-patient impact. The HIT-CS identified a technical failure in system availability and recovery. The ICPS classified the event as a documentation or information incident with potential for severe harm. The SEIPS 2.0 and sociotechnical models highlighted disruptions to monitoring tasks and the organization's reliance on IT intervention. The HFACS-Healthcare attributed the event primarily to organizational influences and preconditions for unsafe acts, with no frontline unsafe acts identified. Convergence across frameworks emphasized system-level contributors. Conclusions: HIT-related monitoring failures in high-acuity settings are best understood as sociotechnical system events rather than isolated technical faults or individual errors. A multi-framework approach provided complementary insights into detection, recovery, and governance vulnerabilities, supporting improved learning and resilience in clinical surveillance systems.

Indexed as

Intensive Care UnitsMedical InformaticsPatient SafetyDigital HealthHumansQualitative Researchclinical information systemsincident classificationintensive care informaticsmonitoring system downtimeresilience engineeringsafety-critical systemssafety incident analysissystem availability failuresystem recovery processestechnology-induced error

Identifiers

PMID41955001
PMCPMC13064593

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.