ArticleEJNMMI physics2026

Impact of dual-energy window scatter correction on technetium image quality across different energy windows in cadmium-zinc-telluride-based SPECT/CT.

Ruyi Zhang, Shen Wang, Yiming Shen, Wei Zheng, Ning Li, Peng Wang, Jian Tan, Zhaowei Meng, Qiang Jia

Abstract read
In one paragraph

Article in EJNMMI physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ruyi ZhangDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Shen WangDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Yiming ShenDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Wei ZhengDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Ning LiDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Peng WangDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Jian TanDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Zhaowei MengDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China. jamesmencius@163.com.ORCID http://orcid.org/0000-0002-4478-878X
Qiang JiaDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China. jiaqiang4321@163.com.

Funding

National Natural Science Foundation of China grants #81571709National Natural Science Foundation of China grants #81971650Tianjin Key Medical Discipline (Specialty) Construction Project TJYXZDXK-001ATianjin Science and Technology Committee Foundation grant #21JCYBJC01820
6 · The paper itself

Abstract

backgroundThe digital cadmium-zinc-telluride (CZT)-based SPECT system offers good energy resolution. However, the impacts of dual-energy window scatter correction on image quality under narrower primary energy windows remain to be determined. This study aimed to assess the impacts of SC (with scatter correction) and NOSC (without scatter correction) on image quality under different primary energy windows.

methodsWe used a standard NEMA/IEC 2007 phantom containing six hollow spheres of various sizes to simulate the human body at four target-to-background ratios (T/B ratio, the ratio of the average radioactive activity concentration in the target region to that in the background region, 32:1, 16:1, 8:1, and 4:1, respectively), by filling with

resultsHigher percent background variability and COV values were present when SC was applied regardless of which energy window, acquisition time, or T/B ratio used, and statistically significant differences were observed between all SC and NOSC groups for both phantoms and patients. For phantoms, percent contrast values of most SC groups were higher than those of NOSC groups. For patients, CNRs and SNRs of SC groups were higher than those of NOSC groups (all P < 0.05). Visually, SC had higher visual scores than NOSC for both phantoms and patients.

conclusionsSC significantly improves image contrast while minimizing concomitant image noise to a great extent and provides good visual image quality across different primary energy windows overall.

Indexed as

CNRCOVCZT SPECT/CTPercent background variabilityPercent contrastPrimary energy windowScatter correctionSNR

Identifiers

PMID41951861
PMCPMC13062129

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.