Evidence map›Paper›PMID 41950248›Full record

ArticlePloS one2026

MaxGRNet: A multi-axis vision transformer with improved generalization for eye disease classification using explainable AI with insertion-deletion operations on fundus images.

Md Mehedi Hasan Santo, Fuyad Hasan Bhoyan, Fuad Ibne Jashim Farhad, Fahmid Al Farid, Sovon Chakraborty, Md Humaion Kabir Mehedi, Jia Uddin, Hezerul Bin Abdul Karim

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Md Mehedi Hasan SantoDepartment of Information Technology, Central Queensland University, Melbourne, Victoria, Australia.
Fuyad Hasan BhoyanDepartment of Computer Science and Engineering, University of Liberal Arts, Dhaka, Bangladesh.
Fuad Ibne Jashim FarhadDepartment of Information Technology, Central Queensland University, Melbourne, Victoria, Australia.
Fahmid Al FaridCentre for Image and Vision Computing (CIVC), COE for Artificial Intelligence, Faculty of Artificial Intelligence and Engineering (FAIE), Multimedia University, Cyberjaya, Selangor, Malaysia.
Sovon ChakrabortyDepartment of Computer Science, Old Dominion University Norfolk, Norfolk, Virginia, United States of America.
Md Humaion Kabir MehediDepartment of Computer Science and Engineering, BRAC University, Dhaka, Bangladesh.ORCID https://orcid.org/0000-0002-5759-022X
Jia UddinAI and Big Data Department, Endicott College, Woosong University, Daejeon, Republic of Korea.ORCID https://orcid.org/0000-0002-3403-4095
Hezerul Bin Abdul KarimCentre for Image and Vision Computing (CIVC), COE for Artificial Intelligence, Faculty of Artificial Intelligence and Engineering (FAIE), Multimedia University, Cyberjaya, Selangor, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Eye diseases, including diabetic retinopathy (DR), glaucoma, and cataracts, represent a major global health concern and can lead to severe visual impairment or blindness if not identified in a timely manner. This study proposes a novel eye disease classification framework based on a multi-axis vision transformer (MaxViT) applied to color fundus images with Explainable Artificial Intelligence (XAI) techniques to enhance model transparency. The proposed architecture integrates transformer-based attention mechanisms with Global Response Normalization (GRN)-based multi-layer perceptron (MLP) layers to capture complex spatial and contextual relationships within fundus images effectively. The model was evaluated on a publicly available eye disease classification dataset using a five-fold cross-validation strategy to assess its robustness and generalization. The experimental results show that the proposed approach consistently outperforms conventional Convolutional Neural Networks (CNNs) and Vision Transformer (ViT) variants, including ResNet50, Swin-T, MaxViT-T, and ViT-B16. The model achieved a macro-averaged test accuracy, precision, and recall values of 96.75%, 96.70%, and 96.80%, respectively, with paired statistical t-tests confirming that these improvements were statistically significant. Rigorous preprocessing techniques were employed to improve data consistency, and XAI-based visual explanations provided insights into the model's decision-making process, supporting interpretability in ophthalmic image analysis. Overall, the proposed MaxViT-based framework is robust and computationally feasible for research-oriented evaluation approaches for automated fundus image classification, highlighting the potential of advanced transformer architectures for future decision-support and research-oriented ophthalmic applications.

Indexed as

Artificial IntelligenceEye DiseasesFundus OculiImage Processing, Computer-AssistedConvolutional Neural NetworksHumansMultilayer Perceptrons

Identifiers

PMID41950248
PMCPMC13061185

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked