Evidence map›Paper›PMID 41948121›Full record

ArticleJournal of hand surgery global online2026

Biomechanical Evaluation of Various Screw Constructs for Proximal Phalanx Base Fracture Fixation.

Mariel McArthur, Miguel A Diaz, Humberto Cardona, Craig Dent, Mitch Daniel, Michael C Doarn, Devin W Collins

Abstract read
In one paragraph

Article in Journal of hand surgery global online, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mariel McArthurPhillip Spiegel Orthopaedic Research Laboratory at the Foundation for Orthopaedic Research and Education, Tampa, FL.
Miguel A DiazPhillip Spiegel Orthopaedic Research Laboratory at the Foundation for Orthopaedic Research and Education, Tampa, FL.
Humberto CardonaPhillip Spiegel Orthopaedic Research Laboratory at the Foundation for Orthopaedic Research and Education, Tampa, FL.
Craig DentPhillip Spiegel Orthopaedic Research Laboratory at the Foundation for Orthopaedic Research and Education, Tampa, FL.
Mitch DanielPhillip Spiegel Orthopaedic Research Laboratory at the Foundation for Orthopaedic Research and Education, Tampa, FL.
Michael C DoarnPhillip Spiegel Orthopaedic Research Laboratory at the Foundation for Orthopaedic Research and Education, Tampa, FL.
Devin W CollinsPhillip Spiegel Orthopaedic Research Laboratory at the Foundation for Orthopaedic Research and Education, Tampa, FL.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate the biomechanical properties of four fixation methods for proximal phalanx base fractures, single antegrade cannulated screw (control), V-pattern, Y-pattern, and K-wire configurations, using a matched pair cadaveric model. Methods: Forty-eight fingers (index through little) from six matched cadaveric hand pairs were included. A standardized transverse base fracture was created in the proximal phalanx. One side of each pair received a single antegrade cannulated screw. Contralateral digits were treated with either a V-pattern (group 1), Y-pattern (group 2), or K-wire configuration (group 3). Specimens underwent 3-point bending, rotational testing, and cantilever bending to failure using a hydraulic test frame. Key metrics included bending stiffness, torsional stiffness, axial displacement, and peak load to failure. Results: The V-pattern demonstrated considerably higher bending stiffness, reduced displacement, greater rotational stiffness, and higher torque resistance compared to controls. While failure displacement was similar, the V-pattern required considerably higher force to fail and showed greater stiffness. The Y-pattern showed no notable differences in bending stiffness or displacement versus controls. However, it had considerably lower rotational stiffness and torque resistance. No differences in failure load, stiffness, or displacement were noted. The K-wire showed considerably lower bending stiffness and higher displacement compared to controls. Rotational metrics and failure parameters showed no notable differences. Conclusions: Among the configurations tested, the V-pattern demonstrated superior biomechanical stability across bending, torsional, and failure testing compared to single antegrade cannulated screw and dual K-wire supporting our hypothesis. These findings support further investigation into its clinical application for improved fixation in proximal phalanx base fractures. Moreover, the addition of a smaller screw to make the Y-pattern did not add considerable strength. Type of study/level of evidence: Diagnostic IV.

Indexed as

Antegrade approachBiomechanicsFractureInternal fixationProximal phalanx

Identifiers

PMID41948121
PMCPMC13052001

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.