Evidence map›Paper›PMID 41948109›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2026

Misalignment After Implantation of One-Piece Hydrophobic Toric Intraocular Lenses: Comparison Among Manufacturers and Generations.

Tomohisa Nishimura, Keiichiro Minami

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Tomohisa NishimuraMikawa Eye Clinic, Saga-city, Saga Prefecture, Japan.
Keiichiro MinamiKK Evidence Slyme, Osaka City, Osaka Prefecture, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study aimed to retrospectively compare postoperative axial misalignment of one-piece hydrophobic toric intraocular lenses (IOLs) from three manufacturers and two different generations. Methods: Clinical records of 420 eyes implanted with six types of toric IOLs were reviewed, including SN6AT3-T9 and CNW0T3-T9 (Alcon, groups SA and CNW, respectively); 355T3-T5 and XY1AT3-T6 (Hoya, groups 355 and XY1A); and ZCT150/225/300/375 and ZCW150/225/300/375 (Johnson & Johnson Surgical Vision, groups ZCT and ZCW, respectively), with 70 eyes in each group. All surgeries were performed using identical surgical equipment and technique, and axial marks were aligned using a surgical guidance system. The axial marker position was measured on postoperative day 1, and the absolute difference from the target position was calculated to determine the degree of misalignment. The rate of misalignment of ≥10 ° was also examined. Results: The median axial misalignments were SA = 2.3 °, CNW = 1.9 °, 355 = 3.8 °, XY1A = 3.1 °, ZCT = 4.3 °, and ZCW = 2.6 °. Misalignments in the 355 and ZCT groups were significantly greater than those in the SA and CNW groups (P < 0.045). Misalignment ≥10 ° was observed in 9 eyes in the 355 group, 6 eyes in the XY1A group, 10 eyes in the ZCT group, and 1 eye in the ZCW group. Conclusion: Toric IOLs from Alcon exhibited the lowest degree of misalignment. A newer-generation IOL with frost-treated haptics (ZCW group) showed reduced misalignment despite no change in material composition. This comparison suggested that IOL material and haptic properties are factors associated with misalignment.

Indexed as

hydrophobic acrylic toric intraocular lensIOL rotationmisalignment

Identifiers

PMID41948109
PMCPMC13050970

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.