Evidence map›Paper›PMID 41939494›Full record

ArticleMedical archives (Sarajevo, Bosnia and Herzegovina)2026

Objective Assessment of Combined Orbital Fat Repositioning and Fat Grafting in Upper Eyelid Hollowing.

Le Huu Dien, Hoang Tuan Anh, Vu Ngoc Lam, Vu Van Duc, Tran Hong Nguyen, Duong Nguyen Viet Anh, Nguyen Thi Hong Van, Tran Thiet Son

Abstract read
In one paragraph

Article in Medical archives (Sarajevo, Bosnia and Herzegovina), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Le Huu DienDepartment of Plastic and Reconstructive Surgery, Hanoi Medical University, Hanoi, Vietnam.
Hoang Tuan AnhDepartment of Plastic and Reconstructive Surgery, Hanoi Medical University, Hanoi, Vietnam.
Vu Ngoc LamDeputy Director of 108 military Central Hospital, Hanoi, Vietnam.
Vu Van DucDepartment of Surgery, Times Hospital, Hanoi, Vietnam.
Tran Hong NguyenDepartment of Surgery, Times Hospital, Hanoi, Vietnam.
Duong Nguyen Viet AnhDepartment of Plastic and Reconstructive Surgery, Hanoi Medical University, Hanoi, Vietnam.
Nguyen Thi Hong VanDepartment of Surgery, Times Hospital, Hanoi, Vietnam.
Tran Thiet SonDepartment of Plastic and Reconstructive Surgery, Hanoi Medical University, Hanoi, Vietnam.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Upper eyelid hollowing is a common manifestation of periorbital aging caused by soft-tissue atrophy and loss of orbital fat volume. Although various corrective techniques have been described, outcome assessment remains largely subjective. High-resolution ultrasonography may provide an objective and quantitative method for evaluating postoperative soft-tissue changes. Objective: The present study aimed to evaluate the effectiveness and stability of combined orbital fat repositioning and microfragmented autologous fat grafting for the correction of moderate upper eyelid hollowing, using high-resolution ultrasonography as an objective assessment tool. Methods: A prospective study was conducted in 35 female patients (70 upper eyelids), aged 40-65 years, with moderate upper eyelid hollowing (Park grade II). All patients underwent combined orbital fat pad repositioning with supplemental microfragmented autologous fat grafting. High-resolution ultrasonography was performed preoperatively and at 1, 3, and 6 months postoperatively to measure the space anterior to the upper eyelid skin (D1) and upper eyelid thickness (D2). Clinical outcomes and patient satisfaction were also evaluated. Results: he mean preoperative hollowing depth was 5.88 ± 0.85 mm, and the mean grafted fat volume was 1.09 ± 0.29 mL. Postoperative ultrasonography demonstrated a significant decrease in D1 and a significant increase in D2 at all postoperative time points compared with baseline (all p < 0.05). No statistically significant differences were observed between the 3- and 6-month follow-up periods (p > 0.05), indicating stabilization of outcomes after 3 months. Overall patient satisfaction was 97.14%. No major complications were observed. Conclusion: Combined orbital fat repositioning and microfragmented autologous fat grafting is a safe and effective technique for correcting moderate upper eyelid hollowing. High-resolution ultrasonography provides an objective, reproducible, and clinically applicable method for postoperative outcome assessment.

Indexed as

Adipose TissueBlepharoplastyEyelidsOrbitAdultAgedFemaleHumansMiddle AgedPatient SatisfactionProspective StudiesTransplantation, AutologousTreatment OutcomeUltrasonographyAutologous fat graftingHigh-resolution ultrasonographyOrbital fat repositioningPeriorbital rejuvenationUpper eyelid hollowing

Identifiers

PMID41939494
PMCPMC13049471

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.